Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 163

The DOI matches its Crossref record.

High-resolution Three-dimensional Magnetic Resonance Angiography and Three-dimensional Spoiled Gradient-recalled Imaging in the Evaluation of Neurovascular Compression in Patients with Trigeminal Neuralgia: A Double-blind Pilot Study

Anderson, Valerie C., Berryhill, Phillip C., Sandquist, Michael A., Ciaverella, David P., Nesbit, Gary M., Burchiel, Kim J. · 2006 · Neurosurgery

Abstract

OBJECTIVE: To assess the value of high-resolution three-dimensional (3D) time-of-flight (TOF) magnetic resonance (MR) angiography and gadolinium (Gad)-enhanced 3D spoiled gradient-recalled imaging in the visualization of neurovascular compression in patients with trigeminal neuralgia. METHODS: Forty-eight patients with unilateral trigeminal neuralgia underwent high-resolution 3D TOF MR angiography. After administration of a contrast agent, a 3D spoiled gradient-recalled sequence (3D Gad) was run. Images were reviewed by a radiologist blinded to clinical details. All patients underwent microvascular decompression surgery. Microdissection of the trigeminal nerve and compressing vessels was videotaped during surgery and reviewed by surgeons uninvolved in patient care. Results from neuroradiological studies were then compared with findings on operative videotapes. RESULTS: MR angiography in combination with 3D Gad imaging identified surgically verified neurovascular contact in 42 of 46 (91%) symptomatic nerves. The offending vessel (artery, vein) was correctly identified in 31 of 41 cases (sensitivity, 76%; specificity, 75%). Neurovascular compression was observed in 71% of asymptomatic nerves with a trend toward greater compression severity on the symptomatic nerve (P < 0.09). Agreement between the direction of neurovascular contact defined by 3D TOF MR angiography and 3D Gad and findings at surgery was good (kappa = 0.78; 95% confidence interval, 0.61-0.94). CONCLUSION: Double-blind assessment of surgical and neuroradiological findings confirms that neurovascular compression can be visualized with good sensitivity in patients with trigeminal neuralgia by 3D TOF MR angiography in combination with Gad-enhanced 3D spoiled gradient-recalled sequences. Anatomic relationships defined by this method can be useful in predicting surgical findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000197117.34888.de

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Anderson, V. C., Berryhill, P. C., Sandquist, M. A., Ciaverella, D. P., Nesbit, G. M., & Burchiel, K. J.
Venue
Neurosurgery
Published
2006-04
Volume
58
Issue
4
Pages
666-673
ISSN
0148-396X (ISSN-L)
OpenAlex
W2035475152
Cited by
163
References
0
FWCI
7.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-resolution Three-dimensional Magnetic Resonance Angiography and Three-dimensional Spoiled Gradient-recalled Imaging in the Evaluation of Neurovascular Compression in Patients with Trigeminal Neuralgia: A Double-blind Pilot Study. https://app.cochat.ai/papers/10.1227/01.neu.0000197117.34888.de
The paper
Anderson, V. C., Berryhill, P. C., Sandquist, M. A., Ciaverella, D. P., Nesbit, G. M., & Burchiel, K. J. (2006). High-resolution Three-dimensional Magnetic Resonance Angiography and Three-dimensional Spoiled Gradient-recalled Imaging in the Evaluation of Neurovascular Compression in Patients with Trigeminal Neuralgia: A Double-blind Pilot Study. Neurosurgery. https://doi.org/10.1227/01.neu.0000197117.34888.de

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.