CoChat

ELECTROCORTICOGRAPHIC FREQUENCY ALTERATION MAPPING: A CLINICAL TECHNIQUE FOR MAPPING THE MOTOR CORTEX

Leuthardt, Eric C., Miller, Kai, Anderson, Nicholas R., Schalk, Gerwin, Dowling, Joshua, Miller, John, Moran, Daniel W., Ojemann, Jeff G. · 2007 · Operative Neurosurgery
Cited by 94

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Electrocortical stimulation (ECS) has been well established for delineating the eloquent cortex. However, ECS is still coarse and inefficient in delineating regions of the functional cortex and can be hampered by after-discharges. Given these constraints, an adjunct approach to defining the motor cortex is the use of electrocorticographic signal changes associated with active regions of the cortex. The broad range of frequency oscillations are categorized into two main groups with respect to the sensorimotor cortex: low and high frequency bands. The low frequency bands tend to show a power reduction with cortical activation, whereas the high frequency bands show power increases. These power changes associated with the activated cortex could potentially provide a powerful tool in delineating areas of the motor cortex. We explore electrocorticographic signal alterations as they occur with activated regions of the motor cortex, as well as its potential in clinical brain mapping applications. METHODS: We evaluated seven patients who underwent invasive monitoring for seizure localization. Each patient had extraoperative ECS mapping to identify the motor cortex. All patients also performed overt hand and tongue motor tasks to identify associated frequency power changes in regard to location and degree of concordance with ECS results that localized either hand or tongue motor function. RESULTS: The low frequency bands had a high sensitivity (88.9-100%) and a lower specificity (79.0-82.6%) for identifying electrodes with either hand or tongue ECS motor responses. The high frequency bands had a lower sensitivity (72.7-88.9%) and a higher specificity (92.4-94.9%) in correlation with the same respective ECS positive electrodes. CONCLUSION: The concordance between stimulation and spectral power changes demonstrate the possible utility of electrocorticographic frequency alteration mapping as an adjunct method to improve the efficiency and resolution of identifying the motor cortex.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000255413.70807.6e

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 94

Metadata

Authors
Leuthardt, E. C., Miller, K., Anderson, N. R., Schalk, G., Dowling, J., Miller, J., Moran, D. W., & Ojemann, J. G.
Venue
Operative Neurosurgery
Published
2007-04
Volume
60
Issue
4
Pages
260-271
ISSN
2332-4252 (ISSN-L)
OpenAlex
W2066579757
Cited by
94
References
3
FWCI
3.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ELECTROCORTICOGRAPHIC FREQUENCY ALTERATION MAPPING: A CLINICAL TECHNIQUE FOR MAPPING THE MOTOR CORTEX. https://app.cochat.ai/papers/10.1227/01.neu.0000255413.70807.6e
The paper
Leuthardt, E. C., Miller, K., Anderson, N. R., Schalk, G., Dowling, J., Miller, J., Moran, D. W., & Ojemann, J. G. (2007). ELECTROCORTICOGRAPHIC FREQUENCY ALTERATION MAPPING: A CLINICAL TECHNIQUE FOR MAPPING THE MOTOR CORTEX. Operative Neurosurgery. https://doi.org/10.1227/01.neu.0000255413.70807.6e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.