Interactive Diffusion Tensor Tractography Visualization for Neurosurgical Planning
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Diffusion tensor imaging (DTI) infers the trajectory and location of large white matter tracts by measuring the anisotropic diffusion of water. DTI data may then be analyzed and presented as tractography for visualization of the tracts in 3 dimensions. Despite the important information contained in tractography images, usefulness for neurosurgical planning has been limited by the inability to define which are critical structures within the mass of demonstrated fibers and to clarify their relationship to the tumor. OBJECTIVE: To develop a method to allow the interactive querying of tractography data sets for surgical planning and to provide a working software package for the research community. METHODS: The tool was implemented within an open source software project. Echo-planar DTI at 3 T was performed on 5 patients, followed by tensor calculation. Software was developed that allowed the placement of a dynamic seed point for local selection of fibers and for fiber display around a segmented structure, both with tunable parameters. A neurosurgeon was trained in the use of software in < 1 hour and used it to review cases. RESULTS: Tracts near tumor and critical structures were interactively visualized in 3 dimensions to determine spatial relationships to lesion. Tracts were selected using 3 methods: anatomical and functional magnetic resonance imaging-defined regions of interest, distance from the segmented tumor volume, and dynamic seed-point spheres. CONCLUSION: Interactive tractography successfully enabled inspection of white matter structures that were in proximity to lesions, critical structures, and functional cortical areas, allowing the surgeon to explore the relationships between them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628 · cited 2×
“16,17,19,21,34,36,38”
BackgroundTracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Reproducibility of quantitative tractography methods applied to cerebral white matter
Wakana, S., Caprihan, A., Panzenboeck, M. M., Fallon, J. H., Perry, M., Gollub, R. L., Hua, K., Zhang, J., Jiang, H., Dubey, P., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.049 · Cited by 1,686
Virtual in vivo interactive dissection of white matter fasciculi in the human brain
Catani, M., Howard, R. J., Pajevic, S., & Jones, D. K. (2002) · NeuroImage · doi:10.1006/nimg.2002.1136 · Cited by 1,637
Cited by
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
Self-citation3D Slicer: A Platform for Subject-Specific Image Analysis, Visualization, and Clinical Support
Kikinis, R., Pieper, S. D., & Vosburgh, K. G. (2014) · Intraoperative Imaging and Image-Guided Therapy · doi:10.1007/978-1-4614-7657-3_19 · Cited by 1,118
Self-citationAn Introduction to Diffusion Tensor Image Analysis
O’Donnell, L. J., & Westin, C.-F. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.12.004 · Cited by 534
Emerging Applications of Bedside 3D Printing in Plastic Surgery
Chae, M. P., Rozen, W. M., McMenamin, P. G., Findlay, M. W., Spychal, R. T., & Hunter-Smith, D. J. (2015) · Frontiers in Surgery · doi:10.3389/fsurg.2015.00025 · Cited by 377
Essayed, W. I., Zhang, F., Unadkat, P., Cosgrove, G. R., Golby, A. J., & O'Donnell, L. J. (2017) · NeuroImage: Clinical · doi:10.1016/j.nicl.2017.06.011 · Cited by 245
“2) (Chamberland et al., 2015; Chamberland et al., 2014; Golby et al., 2011).”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Golby, A. J., Kindlmann, G., Norton, I., Yarmarkovich, A., Pieper, S., & Kikinis, R.
- Venue
- Neurosurgery
- Published
- 2011-02
- Volume
- 68
- Issue
- 2
- Pages
- 496-505
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2102006162
- Cited by
- 115
- References
- 4
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interactive Diffusion Tensor Tractography Visualization for Neurosurgical Planning. https://app.cochat.ai/papers/10.1227/neu.0b013e3182061ebb
- The paper
- Golby, A. J., Kindlmann, G., Norton, I., Yarmarkovich, A., Pieper, S., & Kikinis, R. (2011). Interactive Diffusion Tensor Tractography Visualization for Neurosurgical Planning. Neurosurgery. https://doi.org/10.1227/neu.0b013e3182061ebb
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.