SIXPack a Graphical User Interface for XAS Analysis Using IFEFFIT
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
SIXPack (Sam's Interface for XAS analysis Package), a graphical user interface that allows users simple manipulation and analysis of data, is presented. The modules of SIXPack allow users to: (1) load, calibrate, and average raw data files; (2) perform background subtractions; (3) perform principal component analysis and target transforms; (4) perform least squares fitting of data to standards and functions; (5) perform EXAFS fitting to FEFF phase and amplitude files; (6) create single scattering FEFF phase and amplitude files using a periodic table interface. Novel features of the program allow for the fitted correction of XANES spectra due to self-absorption effects in unknown matrices, which is particularly useful for analysis of geochemical and environmental systems. The core of the XAS analysis routine uses IFEFFIT. SIXPack is developed in Python, is installable across many operating systems and platforms, and is freely available with an Open Source license.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ankudinov, A. L., Ravel, B., Rehr, J. J., & Conradson, S. D. (1998) · Physical Review B · doi:10.1103/physrevb.58.7565 · Cited by 4,357
IFEFFIT : interactive XAFS analysis and FEFF fitting
Newville, M. (2001) · Journal of Synchrotron Radiation · doi:10.1107/s0909049500016964 · Cited by 3,046
Multiple-scattering calculations of x-ray-absorption spectra
Zabinsky, S. I., Rehr, J. J., Ankudinov, A., Albers, R. C., & Eller, M. J. (1995) · Physical Review B · doi:10.1103/physrevb.52.2995 · Cited by 2,944
Determination of the number of factors and the experimental error in a data matrix
Malinowski, E. R. (1977) · Analytical Chemistry · doi:10.1021/ac50012a027 · Cited by 514
Quantitative Speciation of Heavy Metals in Soils and Sediments by Synchrotron X-ray Techniques
Manceau, A., Marcus, M. A., & Tamura, N. (2002) · Reviews in Mineralogy and Geochemistry · doi:10.2138/gsrmg.49.1.341 · Cited by 451
Applications of Synchrotron Radiation in Low-Temperature Geochemistry and Environmental Science
(2002) · De Gruyter eBooks · doi:10.1515/9781501508882 · Cited by 218
Malinowski, E. R. (1978) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)83099-3 · Cited by 158
Cited by
Identification of Highly Active Fe Sites in (Ni,Fe)OOH for Electrocatalytic Water Splitting
Friebel, D., Louie, M. W., Bajdich, M., Sanwald, K. E., Cai, Y., Wise, A. M., Cheng, M.-J., Sokaras, D., Weng, T.-C., Alonso-Mori, R., et al. (2015) · Journal of the American Chemical Society · doi:10.1021/ja511559d · Cited by 2,732
Bordiga, S., Groppo, E., Agostini, G., van Bokhoven, J. A., & Lamberti, C. (2013) · Chemical Reviews · doi:10.1021/cr2000898 · Cited by 643
Levard, C., Reinsch, B. C., Michel, F. M., Oumahi, C., Lowry, G. V., & Brown, G. E. (2011) · Environmental Science & Technology · doi:10.1021/es2007758 · Cited by 478
Size-Controlled Dissolution of Organic-Coated Silver Nanoparticles
Ma, R., Levard, C., Marinakos, S. M., Cheng, Y., Liu, J., Michel, F. M., Brown, G. E., & Lowry, G. V. (2012) · Environmental Science & Technology · doi:10.1021/es201686j · Cited by 415
Adsorption of antimony onto iron oxyhydroxides: Adsorption behavior and surface structure
Guo, X., Wu, Z., He, M., Meng, X., Jin, X., Qiu, N., & Zhang, J. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.05.025 · Cited by 406
Metadata
- Authors
- Webb, S. M.
- Venue
- Physica Scripta
- Publisher
- IOP Publishing
- Published
- 2005
- Pages
- 1011
- ISSN
- 0031-8949 (ISSN-L)
- OpenAlex
- W1993596116
- Cited by
- 1,054
- References
- 7
- FWCI
- 23.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.