The DOI matches its Crossref record.
Tracking of cell surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera: Low-density lipoprotein and influenza virus receptor mobility at 4°C
Abstract
A fluorescence imaging system, based on using a cooled slow-scan CCD camera, has been developed for tracking receptors on the surfaces of living cells. The technique is applicable to receptors for particles such as lipoproteins and viruses that can be labeled with a few tens of fluorophores. The positions of single particles in each image are determined to within 25 nm by fitting the fluorescence distribution to a two-dimensional Gaussian function. This procedure also provides an accurate measure of intensity, which is used as a tag for automated tracking of particles from frame to frame. The method is applied to an investigation of the mobility of receptors for LDL and influenza virus particles on human dermal fibroblasts at 4°C. In contrast to previous studies by FRAP (fluorescence recovery after photo bleaching), it is found that receptors have a low but measurable mobility at 4°C. Analysis of individual particle tracks indicates that whilst some receptors undergo random diffusion, others undergo directed motion (flow) or diffusion restricted to a domain. A procedure is proposed for subdividing receptors according to their different types of motion and hence determining their motional parameters. The finding that receptors are not completely immobilised at 4°C is significant for studies of receptor distributions performed at this temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SINGLE-PARTICLE TRACKING:Applications to Membrane Dynamics
Saxton, M. J., & Jacobson, K. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.373 · Cited by 1,810
Feature point tracking and trajectory analysis for video imaging in cell biology
Sbalzarini, I. F., & Koumoutsakos, P. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.06.002 · Cited by 1,392
Kusumi, A., Sako, Y., & Yamamoto, M. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81253-0 · Cited by 1,053
Quantitative Comparison of Algorithms for Tracking Single Fluorescent Particles
Cheezum, M. K., Walker, W. F., & Guilford, W. H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75884-5 · Cited by 896
Atg9 vesicles are an important membrane source during early steps of autophagosome formation
Yamamoto, H., Kakuta, S., Watanabe, T. M., Kitamura, A., Sekito, T., Kondo-Kakuta, C., Ichikawa, R., Kinjo, M., & Ohsumi, Y. (2012) · Journal of Cell Biology · doi:10.1083/jcb.201202061 · Cited by 659
Metadata
- Authors
- Anderson, C. M., Georgiou, G. N., Morrison, I. E. G., Stevenson, G. V. W., & Cherry, R. J.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 1992-02-01
- Volume
- 101
- Issue
- 2
- Pages
- 415-425
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2102938423
- Cited by
- 244
- References
- 0
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tracking of cell surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera: Low-density lipoprotein and influenza virus receptor mobility at 4°C. https://app.cochat.ai/papers/10.1242/jcs.101.2.415
- The paper
- Anderson, C. M., Georgiou, G. N., Morrison, I. E. G., Stevenson, G. V. W., & Cherry, R. J. (1992). Tracking of cell surface receptors by fluorescence digital imaging microscopy using a charge-coupled device camera: Low-density lipoprotein and influenza virus receptor mobility at 4°C. Journal of Cell Science. https://doi.org/10.1242/jcs.101.2.415
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.