Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record.

A quantitative analysis of connexin-specific permeability differences of gap junctions expressed in HeLa transfectants and X enopus oocytes

Cao, Fengli, Eckert, Reiner, Elfgang, Claudia, Nitsche, Johannes M., Snyder, Scott A., Hülser, Dieter F., Willecke, Klaus, Nicholson, Bruce J.·1998·Journal of Cell Science

Abstract

Gap junctions provide direct intercellular communication by linking adjacent cells with aqueous pores permeable to molecules up to 1 kDa in molecular mass and 8-14 Å in diameter. The identification of over a dozen connexins in the mammalian gap junction family has stimulated interest in the functional significance of this diversity, including the possibility of selectivity for permeants as seen in other channel classes. Here we present a quantitative comparison of channel permeabilities of different connexins expressed in both HeLa transfectants (rat Cx26, rat Cx32 and mouse Cx45) and Xenopus oocytes (rat Cx26 and rat Cx32). In HeLa cells, we examined permeability to two fluorescent molecules: Lucifer Yellow (LY: anionic, MW 457) and 4′,6-diamidino-2-phenylindole, dihydrochloride (DAPI, cationic, MW 350). A comparison of the kinetics of fluorescent dye transfer showed Cx32, Cx26 and Cx45 to have progressively decreasing permeabilities to LY, but increasing permeabilities to DAPI. This pattern was inconsistent with selection based on physical size of the probe, nor could it be accounted for by the differences between clones in the electrical conductance of the monolayers. In Xenopus oocytes, where electrical and dye coupling could be assessed in the same cells, Cx32 coupled oocytes showed an estimated 6-fold greater permeability to LY than those coupled by Cx26, a comparable result to that seen in HeLa cells, where an approximately 9-fold difference was seen. The oocyte system also allowed an examination of Cx32/Cx26 heterotypic gap junction that proved to have a permeability intermediate between the two homotypic forms. Thus, independent of the expression system, it appears that connexins show differential permeabilities that cannot be predicted based on size considerations, but must depend on other features of the probe, such as charge.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1242/jcs.111.1.31

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Cao, F., Eckert, R., Elfgang, C., Nitsche, J. M., Snyder, S. A., Hülser, D. F., Willecke, K., & Nicholson, B. J.
Venue
Journal of Cell Science
Published
1998-01-01
Volume
111
Issue
1
Pages
31-43
ISSN
  • 0021-9533 (ISSN-L)
  • 1477-9137
OpenAlex
W2189568229
Cited by
171
References
0
FWCI
5.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A quantitative analysis of connexin-specific permeability differences of gap junctions expressed in HeLa transfectants and X enopus oocytes. https://app.cochat.ai/papers/10.1242/jcs.111.1.31
The paper
Cao, F., Eckert, R., Elfgang, C., Nitsche, J. M., Snyder, S. A., Hülser, D. F., Willecke, K., & Nicholson, B. J. (1998). A quantitative analysis of connexin-specific permeability differences of gap junctions expressed in HeLa transfectants and X enopus oocytes. Journal of Cell Science. https://doi.org/10.1242/jcs.111.1.31

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.