Cited by 107Tendon Structure and TreatmentCellular Mechanics and InteractionsOsteoarthritis Treatment and Mechanisms

Mechanical loading regulates tenascin‐C expression in the osteotendinous junction

Järvinen, Tero A. H., Jozsa, Laszlo, Kannus, Pekka, Järvinen, Teppo L. N., Kvist, Martti, Hurme, Timo, Isola, Jorma, Kalimo, Hannu +1 more·1999·Journal of Cell Science

Abstract

Elastic extracellular matrix protein tenascin-C (TN) has very restricted expression in normal tissues, but is expressed in large quantities during embryogenesis and hyperplastic processes. To examine the importance of mechanical stress on the regulation of TN expression in vivo, the effects of various mechanical loading states (immobilization and three forms of subsequent remobilization) on the expression of TN were studied immunohistochemically at the bone-tendon attachment of the rat quadriceps muscle. This osteotendinous junction (OTJ) was selected as study site, since it receives its mechanical stimuli only from muscle contracting activity, which is easy to block by cast immobilization. TN was expressed abundantly in the normal OTJ. Following the removal of the mechanical stress from the junction by cast-immobilization of three weeks, the immunoreactivity of TN was almost completely absent. Normal mechanical stress in the form of free remobilization of eight weeks (free cage activity) resulted in a slight increase in TN expression, but could not restore the expression of TN to the level of the healthy contralateralleg. After the application of the increased mechanical stress (intensified remobilization of the eight weeks by low- or high-intensity treadmill running), the distribution and immunoreactivity of TN reached the level of the healthy contralateral limb in the low-intensity running group or even exceeded that in the high-intensity running group. High TN expression was seen around the chondrocytes and fibroblasts of the OTJ as well as around the collagen fibers of the tendon belly. We conclusively show that mechanical strain regulates the expression of TN in vivo, and propose that mechanical stress is a major regulator of TN expression in fibroblasts and chondrocytes. This may be an important aspect of the regulation of TN expression during embryogenesis, tendon degeneration, wound healing, bone formation, and in the other normal or regenerative morphogenetic processes TN is postulated to take part in.

Integrity signals

Registry

Crossref · 10.1242/jcs.112.18.3157

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Tenascin C is an adhesion-modulating ECM molecule that is not normally produced by fibroblasts in the endomysium along muscle fibres, except for those fibres close to the myotendinous junction.

    “Tenascin C is an adhesion-modulating ECM molecule that is not normally produced by fibroblasts in the endomysium along muscle fibres, except for those fibres close to the myotendinous junction (Järvinen et al. 1999(Järvinen et al. , 2000)).”

    From Myofibre damage in human skeletal muscle: effects of electrical stimulation <i>versus</i> voluntary contraction (2007) · cites this paper as Järvinen et al. 1999(Järvinen et al. , 2000)

The citation lists haven’t been fetched yet

References 46 · Cited by 107

Authors
Järvinen, T. A. H., Jozsa, L., Kannus, P., Järvinen, T. L. N., Kvist, M., Hurme, T., Isola, J., Kalimo, H., & Järvinen, M.
Affiliations
  • Tampere University (FI)
  • 3 Department of Morphology, National Institute of Traumatology, Budapest, Hungary
  • Urho Kaleva Kekkonen Institute (FI)
  • Paavo Nurmen Säätiö (FI)
  • University of Turku (FI)
Corresponding author
  • Järvinen, Tero A. H.
  • Kannus, Pekka
  • Järvinen, Teppo L. N.
  • Kvist, Martti
  • Hurme, Timo
  • Isola, Jorma
  • Kalimo, Hannu
  • Järvinen, Markku
Venue
Journal of Cell Science
Published
1999-09-15
Volume
112
Issue
18
Pages
3157-3166
ISSN
  • 0021-9533 (ISSN-L)
  • 1477-9137
OpenAlex
W2186225470
Cited by
107
References
46
Citations by year
2026: 3 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 6 · 2019: 5 · 2018: 6 · 2017: 4 · 2015: 3 · 2014: 6 · 2013: 5 · 2012: 2
FWCI
3.75
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Cell Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
Keywords
tenascin-C, mechanical loading, mechanical stress, cast immobilization, treadmill running, extracellular matrix, chondrocytes, fibroblasts, tendons, quadriceps, gene expression regulation
MeSH terms
Animals, Bone and Bones, Fibroblasts, Immobilization, Immunohistochemistry, Male, Stress, Mechanical, Tendons, Rats, Sprague-Dawley, Tenascin, Chondrocytes, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review