CoChat

Freeze-fracture evidence for gap junctions connecting the axon terminals of dipteran photoreceptors

Shaw, S. R., Stowe, S. · 1982 · Journal of Cell Science
Cited by 36

The DOI matches its Crossref record.

Abstract

The six photoreceptor terminals entering each synaptic cartridge in higher Diptera (flies) are known to be connected reciprocally by small junctions with reduced membrane spacing, so-called ‘close appositions’, but the nature of these sites is currently in dispute. Claims have been made that they are gap junctions, whilst counter-claims have denied this. From freeze-fractured replicas from Lucilia, we conclude that bow-shaped particle groupings, seen on the membrane P fracture face, have been wrongly equated by previous workers to the close appositions. They do not connect between receptors, and probably correspond instead to the frequent chemically mediated ‘tetrad’ synapses to postsynaptic cells. On the opposite (E) face, different, small assemblies of particles are identified here for the first time, which actually do connect the membranes of adjacent terminals. These form roundish, depressed maculae averaging 0 · 13 μm across, containing groups of 30 – 40 irregularly packed, irregularly sized particles of mean diameter 11 · 8 nm, with a dark dot sometimes visible at their apices. These maculae thus possess all the freeze-fracture attributes considered necessary to define an arthropod gap junction. The size range and distribution of the maculae are as expected if they are to be identified with the close appositions seen in sections, and some cross-fractures suggest this correspondence directly. The gap width at the apposition, 4 8 nm, is larger than that usually quoted for a gap junction, but actually falls within the limits of the few accurate determinations in the literature on arthropods. Both sections and replicas confirm that the maculae)appositions are much more numerous than previously thought, with up to 62 on each terminal, spaced about 1 μm apart. The total junctional area coupling a pair of terminals is comparatively large, about 0 · 4 μm2, and similar to the cross-sectional area of the incoming receptor axon as this approaches the cartridge. The junctions are therefore likely candidates to account for the strong electrical coupling recently detected between terminals. The junctions are distributed throughout the synaptic cartridge and not solely confined to its distal end, as most previous workers have contended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1242/jcs.53.1.115

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
Shaw, S. R., & Stowe, S.
Venue
Journal of Cell Science
Published
1982-02-01
Volume
53
Issue
1
Pages
115-141
ISSN
  • 0021-9533 (ISSN-L)
  • 1477-9137
OpenAlex
W4379046026
Cited by
36
References
0
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Freeze-fracture evidence for gap junctions connecting the axon terminals of dipteran photoreceptors. https://app.cochat.ai/papers/10.1242/jcs.53.1.115
The paper
Shaw, S. R., & Stowe, S. (1982). Freeze-fracture evidence for gap junctions connecting the axon terminals of dipteran photoreceptors. Journal of Cell Science. https://doi.org/10.1242/jcs.53.1.115

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.