The DOI matches its Crossref record.
A new vacuum-operated stress-providing instrument that applies static or variable duration cyclic tension or compression to cells in vitro
Abstract
An instrument providing cyclic stress to cells cultured in vitro has been developed. The unit uses a vacuum to deform a plastic Petri dish yielding 0·13% compression to cells on the inner surface, measured by strain gauge recordings. A regimen of 25 s stress and 5 min relaxation induced no significant change in synthesis of a 45×103Mr protein that comigrates with actin, whereas a 52× 103Mr protein that comigrated with tubulin decreased from 12·7 ± 0·451% of the total protein synthesized in control, static cells to 8·53 ± 0·182% in stressed cells. The unit may have a broad application in monitoring biochemical changes in response to stress in cells such as muscle, lung, tendon, ligament and bone that are normally subjected to tension or compression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Meikle, M. C. (2005) · The European Journal of Orthodontics · doi:10.1093/ejo/cjl001 · Cited by 560
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Mechanical strain induces growth of vascular smooth muscle cells via autocrine action of PDGF.
Wilson, E., Mai, Q., Sudhir, K., Weiss, R. H., & Ives, H. E. (1993) · The Journal of cell biology · doi:10.1083/jcb.123.3.741 · Cited by 364
The FOXO3a Transcription Factor Regulates Cardiac Myocyte Size Downstream of AKT Signaling
Skurk, C., Izumiya, Y., Maatz, H., Razeghi, P., Shiojima, I., Sandri, M., Sato, K., Zeng, L., Schiekofer, S., Pimentel, D., et al. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m500528200 · Cited by 353
Pimentel, D. R., Amin, J. K., Xiao, L., Miller, T., Viereck, J., Oliver-Krasinski, J., Baliga, R., Wang, J., Siwik, D. A., Singh, K., et al. (2001) · Circulation Research · doi:10.1161/hh1701.096615 · Cited by 332
Metadata
- Authors
- Banes, A. J., Gilbert, J., Taylor, D., & Monbureau, O.
- Venue
- Journal of Cell Science
- Publisher
- The Company of Biologists
- Published
- 1985-04-01
- Volume
- 75
- Issue
- 1
- Pages
- 35-42
- ISSN
- 0021-9533 (ISSN-L)
- 1477-9137
- OpenAlex
- W2143873872
- Cited by
- 404
- References
- 0
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new vacuum-operated stress-providing instrument that applies static or variable duration cyclic tension or compression to cells in vitro. https://app.cochat.ai/papers/10.1242/jcs.75.1.35
- The paper
- Banes, A. J., Gilbert, J., Taylor, D., & Monbureau, O. (1985). A new vacuum-operated stress-providing instrument that applies static or variable duration cyclic tension or compression to cells in vitro. Journal of Cell Science. https://doi.org/10.1242/jcs.75.1.35
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.