Comparison of integrated micro-electrical-mechanical system and piezoelectric accelerometers for machine condition monitoring
The DOI matches its Crossref record; 8 of the 9 references it cites were found in a registry or an index.
Abstract
The design and implementation of instrumentation to collect real-time vibrational data from a quasi-steady state machine (a dry vacuum pump) for fault prediction diagnostics is presented. When simultaneous multiple data collection points are required on the same machinery, the use of conventional transducers such as piezoelectric accelerometers becomes impractical due to their price, as each needs an expensive associated charge amplifier. The use of inexpensive micromachined integrated micro-electrical-mechanical system accelerometers such as ADXL105 has been explored here as an alternative to piezoelectric accelerometers for obtaining reliable and predictable data for diagnostics. Surface micromachined accelerometers are a new technology and their usage for vibrational analysis has been conservative due to concerns over increased noise levels and tolerance to high temperatures. In this article, it is shown that such concerns can be allayed. The time and frequency domain vibration signatures obtained using both types of accelerometers are compared. The study shows that ADXL105 accelerometers can be an effective alternative low-cost high-quality solution for machine condition monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was found that MEMS accelerometer's sensitivity is more stable compared with the piezoelectric accelerometers and this low-cost MEMS accelerometer can be a good alternative to the high-cost piezoelectric accelerometer.”
From Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review (2021) · cites this paper as [44]
Citations
Cites
Spectrum analysis—A modern perspective
Kay, S. M., & Marple, S. L. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.12184 · Cited by 3,146
Digital Spectral Analysis with Applications.
Porat, B., & Marple, S. L. (1988) · Mathematics of Computation · doi:10.2307/2008605 · Cited by 2,644
Digital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
Tandon, N., & Choudhury, A. (1999) · Tribology International · doi:10.1016/s0301-679x(99)00077-8 · Cited by 1,351
Selection of the order of autoregressive models for spectral analysis of doppler ultrasound signals
Schlindwein, F. S., & Evans, D. H. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90089-u · Cited by 68
Self-citationDiagnostic Monitoring of Rolling-Element Bearings by High-Frequency Resonance Technique
Prashad, H., Ghosh, M., & Biswas, S. (1985) · A S L E Transactions · doi:10.1080/05698198508981641 · Cited by 53
A real-time autoregressive spectrum analyzer for Doppler ultrasound signals
Schlindwein, F. S., & Evans, D. (1989) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(89)90070-7 · Cited by 50
Self-citation
Research works printed but not linked: 6
- Sabin E., 1995, Semicond. Int., 18, 249
- Mechefske C. K., 1993, Brit. J. Non-Destr. Test., 35, 574
- Doscher J., 1999, Analogue Dialogue, 33, 27
- Doscher J. Using iMEMS accelerometers in instrumentation applications. Proceedings of the 45th International Instrumentation Symposium, Instrument Society of America, 1999, pp. 395–404.
- Doscher J., 1997, Sensors, 14, 33
- 1999, ADXL105, Datasheet
Cited by
Vibration Analysis for Machine Monitoring and Diagnosis: A Systematic Review
Mohd Ghazali, M. H., & Rahiman, W. (2021) · Shock and Vibration · doi:10.1155/2021/9469318 · Cited by 249
A survey of health monitoring systems for wind turbines
Wymore, M. L., Van Dam, J. E., Ceylan, H., & Qiao, D. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.110 · Cited by 205
Suitability of MEMS Accelerometers for Condition Monitoring: An experimental study
Albarbar, A., Mekid, S., Starr, A., & Pietruszkiewicz, R. (2008) · Sensors · doi:10.3390/s8020784 · Cited by 162
“There are a number of research studies in the literature [1-9] about MEMS accelerometers construction, mounting considerations, and measurement principle and performance evaluations.”
Performance evaluation of MEMS accelerometers
Albarbar, A., Badri, A. E., Sinha, J. K., & Starr, A. G. (2008) · Measurement · doi:10.1016/j.measurement.2008.12.002 · Cited by 131
“Thanagasundram and Schlindwein [9] have used the MEMS accelerometer together with a conventional accelerometer for measuring the vibration of a pump during its normal operation.”
BackgroundMethodMEMS accelerometers for mechanical vibrations analysis: a comprehensive review with applications
Varanis, M. V. M., Silva, A., Mereles, A., & Pederiva, R. (2018) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-018-1445-5 · Cited by 142
Measurement and evaluation of the effect of vibration on fruits in transit—Review
Fernando, I., Fei, J., Stanley, R. A., & Enshaei, H. (2018) · Packaging Technology and Science · doi:10.1002/pts.2409 · Cited by 78
A microfluidic Coulter counting device for metal wear detection in lubrication oil
Murali, S., Jagtiani, A. V., Xia, X., Carletta, J. E., & Zhe, J. (2009) · Review of Scientific Instruments · doi:10.1063/1.3072665 · Cited by 52
Vogl, A., Wang, D. T., Storås, P., Bakke, T., Taklo, M. M. V., Thomson, A., & Balgård, L. (2009) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2009.04.011 · Cited by 49
Proving MEMS Technologies for Smarter Railway Infrastructure
Milne, D., Pen, L. L., Watson, G. V. R., Thompson, D., Powrie, W. D., Hayward, M., & Morley, S. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.06.222 · Cited by 41
“Previous studies benchmarking MEMS against piezo-electric accelerometers found the accuracy of those MEMS sensors tested to be insufficient for vibration measurement (Albarbar et al., 2009, Thanagasundram and Schlindwein, 2006).”
MethodLiu, Y., Zhao, Y., Wang, W., Sun, L., & Jiang, Z. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.08.033 · Cited by 35
CEEMD-assisted kernel support vector machines for bearing diagnosis
Lu, Y., Xie, R., & Liang, S. Y. (2020) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-019-04858-w · Cited by 34
Milne, D., Pen, L. L., Thompson, D., & Powrie, W. D. (2018) · Proceedings of the Institution of Mechanical Engineers Part F Journal of Rail and Rapid Transit · doi:10.1177/0954409718762172 · Cited by 32
A typical filter design to improve the measured signals from MEMS accelerometer
Badri, A. E., Sinha, J. K., & Albarbar, A. (2010) · Measurement · doi:10.1016/j.measurement.2010.08.011 · Cited by 29
A fault detection tool using analysis from an autoregressive model pole trajectory
Thanagasundram, S., Spurgeon, S. K., & Schlindwein, F. S. (2008) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2008.03.044 · Cited by 26
“The acceleration signal was captured on the pump housing directly over the bearing casing on the HV for normal (no-fault) and faulty conditions using two different types of accelerometers, namely, a surface micromachined accelerometer ADXL105 and a Brüel and Kjær (B&K) 4370V accelerometer which were mounted radially o…”
MethodSelf-citationJiang, W., Spurgeon, S. K., Twiddle, J. A., Schlindwein, F. S., Feng, Y., & Thanagasundram, S. (2007) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes544 · Cited by 23
Self-citationChan, Y. J., & Huang, J.-W. (2017) · Mechatronics · doi:10.1016/j.mechatronics.2017.04.006 · Cited by 19
Electromechanical Vibration Characteristics of Porous Bimorph and Unimorph Doubly Curved Panels
Askari, M., Brusa, E. G. M., & Delprete, C. (2020) · Actuators · doi:10.3390/act9010007 · Cited by 14
“energy harvesters [15–20], piezoelectric transducers [21], mechatronic handling devices [22], adaptive optics in space telescopes [23–25], damping systems [26,27], and continues monitoring systems [28,29].”
BackgroundA Novel Scalable Digital Data Acquisition System for Industrial Condition Monitoring
Toscani, A., Immovilli, F., Pinardi, D., & Cattani, L. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3301521 · Cited by 13
High accurate detection method for aortic valve opening of seismocardiography signals
Zheng, C., Peng, W., Huang, T., Eldar, Y. C., & Yu, M. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.105484 · Cited by 12
Low-Cost Condition Monitoring System for Smart Buildings and Industrial Applications
Toscani, A., Rocchi, N., Pinardi, D., Binelli, M., Saccenti, L., Farina, A., Pavoni, S., & Vanali, M. (2023) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2023.3326784 · Cited by 11
“They provide electromagnetic noise immunity, and their performance is constantly improving [25], [26].”
BackgroundNon-destructive stiffness detection of utility wooden poles using wireless MEMS sensor
Tsang, K. M., & Chan, W. L. (2011) · Measurement · doi:10.1016/j.measurement.2011.03.025 · Cited by 9
A Method to Calibrate the Measured Responses by MEMS Accelerometers
Badri, A. E., Sinha, J. K., & Albarbar, A. (2010) · Strain · doi:10.1111/j.1475-1305.2010.00764.x · Cited by 9
“A few earlier researches gave comparison of the performance between the MEMS and conventional accelerometers, mainly related to the frequency content in the spectrum of the measured signals [10, 11].”
ResultWideband piezoelectric mems vibration sensor
Yaghootkar, B., Azimi, S., & Bahreyni, B. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808651 · Cited by 8
“In recent years, vibration signature monitoring has become a powerful tool in many applications such as machines condition monitoring, constructions health monitoring, security screening, and more [1-3].”
MethodCondition monitoring of wind turbine blades using MEMS accelerometers
Esu, O. O., Flint, J. A., & Watson, S. J. (2013) · Loughborough University Research Repository (Loughborough University) · Cited by 7
Real-Time Vibration Monitoring Using MEMS Vibration Sensors
Ghazali, M. H. M., & Rahiman, W. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-16-8129-5_56 · Cited by 4
On-Shaft Vibration Measurement Using a MEMS Accelerometer for Faults Diagnosis in Rotating Machines
Elnady, M. (2013) · Research Explorer (The University of Manchester) · Cited by 3
Vibration-based condition monitoring of wind turbine blades
Esu, O. O. (2016) · Loughborough University Institutional Repository (Loughborough University) · Cited by 3
Performance Improvement of MEMS Accelerometers in Vibration Based Diagnosis
Badri, A. E. (2011) · Research Explorer (The University of Manchester) · Cited by 3
Laña, I., Bascoy, P. G., Aranguren, A., Gil, S., & Landa-Torres, I. (2024) · IEEE International Conference on Omni-layer Intelligent Systems (COINS) · doi:10.1109/coins61597.2024.10622240 · Cited by 1
“On one hand, the deployment of such sensing furnishings can lead to substantial costs [3], while the specialization of deployed sensors could disregard the detection of some failure modes (e.g., a piezoelectric sensor could be unable to detect failures related to high temperatures).”
BackgroundDevelopment of wireless vibration transducer based on MEMS accelerometer
Олійник, П. Б. (2016) · Eastern-European Journal of Enterprise Technologies · doi:10.15587/1729-4061.2016.71954 · Cited by 1
Design of wireless robust measurement filter based on differential geometry
Deng, C., & Zhang, J. (2019) · IET Wireless Sensor Systems · doi:10.1049/iet-wss.2018.5190 · Cited by 1
General Bayesian approach for manufacturing equipment diagnostics using sensor fusion
Locks, S. I. (2016) · SMARTech Repository (Georgia Institute of Technology)
Piezoresistive Accelerometer Based on Amorphous Carbon Films
Zhang, Q., Pang, X., & Zhao, Y. (2024) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors60989.2024.10785215
“[1].”
Performance Analysis of Blast-Induced Ground Vibration Measuring Sensors at Low-Frequency Excitation
Dey, K. K., Ghosh, S., & Pal, S. K. (2025) · Mineral Metal Energy Oil Gas and Aggregate · doi:10.18311/2meoga/2024/v1i4/45576
Triqadafi, A. O., Theresa, A., Dharmawan, H. A., & Sakti, S. P. (2026) · AIP conference proceedings · doi:10.1063/5.0348336
Metadata
- Authors
- Thanagasundram, S., & Schlindwein, F. S.
- Affiliations
- University of Leicester (GB)
- ORCID
- Schlindwein, F S
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Publisher
- SAGE Publications
- Published
- 2006-08-01
- Volume
- 220
- Issue
- 8
- Pages
- 1135-1146
- ISSN
- 0263-7154 (ISSN-L)
- 0954-4062
- 2041-2983
- OpenAlex
- W2064936868
- Cited by
- 36
- References
- 9
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 5 · 2015: 1 · 2013: 2 · 2012: 1
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science (publishedVersion)
- Leicester Research Archive (University of Leicester) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Keywords
- machine condition monitoring, MEMS accelerometer, piezoelectric accelerometer, vibration analysis, dry vacuum pump, fault prediction, surface micromachining, low-cost instrumentation, vibration signatures
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.