Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The modulus of elasticity of cubes of cancellous bone, tested in three orthogonal directions, was measured along with apparent density, fabric (measured using image analysis techniques), connectivity and mineral volume fraction. Multiple regression was used to relate Young's modulus and the explanatory variables. The most important explanatory variable was apparent density; fabric was also important. Connectivity was highly correlated with apparent density, and so it is difficult to assign relative weights to these two variables. However, both have a significant, and separate, effect on Young's modulus. The total variance in Young's modulus explained by these three variables was about 85 per cent. This implies that other explanatory variables are either unimportant or highly correlated with the variables listed above. Mineral volume fraction is shown to be an unimportant variable, and arguments are produced why this is to be expected, even though it is highly important in explaining the variation in Young's modulus of compact bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579
Cited by
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680
The behavior of adaptive bone-remodeling simulation models
Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90056-7 · Cited by 628
Mechanical and textural properties of pelvic trabecular bone
Dalstra, M., Huiskes, R., Odgaard, A., & van Erning, L. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90014-6 · Cited by 358
Metadata
- Authors
- Hodgskinson, R., & Currey, J. D.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 1990-03
- Volume
- 204
- Issue
- 1
- Pages
- 43-52
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2111691561
- Cited by
- 88
- References
- 2
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone. https://app.cochat.ai/papers/10.1243/pime_proc_1990_204_227_02
- The paper
- Hodgskinson, R., & Currey, J. D. (1990). Effects of Structural Variation on Young's Modulus of Non-Human Cancellous Bone. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/pime_proc_1990_204_227_02
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.