CoChat

The Effect of Variation in Structure on the Young's Modulus of Cancellous Bone: A Comparison of Human and Non-Human Material

Hodgskinson, R, Currey, J D · 1990 · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Cited by 135

The DOI matches its Crossref record.

Abstract

The Young's modulus of cubes of human cancellous bone was measured in three orthogonal directions. Apparent density and mineral volume fraction were also measured, as were two architectural variables, fabric and connectivity, which were determined using image analysis techniques. Multiple regression was used to relate the Young's modulus to the four explanatory variables. The results from this study are compared with those obtained from a previous investigation using non-human cancellous bone. The relationships revealed by the two studies are very similar. It was possible to explain approximately 93 per cent of the variance in Young's modulus using the four variables in this present study. Apparent density is the major explanatory variable in both studies and shows a strong correlation with connectivity. In common with the non-human study the measure of fabric is a worthwhile explanatory variable; however, connectivity and mineral volume fraction are relatively unimportant. The four explanatory variables contribute to a successful model for the prediction of Young's modulus. Any other candidate variables are likely to be unimportant or be highly correlated with those already investigated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1243/pime_proc_1990_204_240_02

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 135

Metadata

Authors
Hodgskinson, R., & Currey, J. D.
Venue
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Published
1990-06
Volume
204
Issue
2
Pages
115-121
ISSN
  • 0954-4119 (ISSN-L)
  • 2041-3033
OpenAlex
W2074283225
Cited by
135
References
0
FWCI
2.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Variation in Structure on the Young's Modulus of Cancellous Bone: A Comparison of Human and Non-Human Material. https://app.cochat.ai/papers/10.1243/pime_proc_1990_204_240_02
The paper
Hodgskinson, R., & Currey, J. D. (1990). The Effect of Variation in Structure on the Young's Modulus of Cancellous Bone: A Comparison of Human and Non-Human Material. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1243/pime_proc_1990_204_240_02

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.