Comparison of a continuous and discontinuous graded treadmill test for maximal oxygen uptake
Abstract
The purpose of the study was to compare a single session continuous-graded treadmill protocol for determining maxVo2 in healthy male subjects with the multi-session discontinuous-graded treadmill procedure described by Taylor and his co-workers. Twenty young adults served as subjects for the study. The treadmill protocols were administered in random order to all subjects. The total experiment for each subject was completed within a two-week time span. No significant differences in mean Vo2 were found between the two test procedures. To establish the similarity of the two tests, confidence limits for the differences between means were calculated for the continuous test versus the discontinuous procedure for various samples sizes. The data support the hypothesis that the continuous test applied permits reasonably accurate measurement of maxVo2 in group studies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These results confirm the myriad of research indicating that utilization of a discontinuous protocol to assess V O 2max does not provide any additional testing validity (12, 24, 26, 27).”
From Comparison of a Continuous and Discontinuous GXT on VO2 in Resistance-Trained and Endurance-Trained Males (2022) · cites this paper as [26]
In the citing paper
“Multiple studies have found there to be no differences in V O 2peak when comparing a discontinuous GXT protocol to a continuous protocol (12, 24, 26, 27).”
From Comparison of a Continuous and Discontinuous GXT on VO2 in Resistance-Trained and Endurance-Trained Males (2022) · cites this paper as [26]
Citations
Cited by
(2022) · International Journal of Exercise Science · doi:10.70252/nhay2400 · Cited by 3
Metadata
- Authors
- MAKSUD, M. G., & COUTTS, K. D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1971
- Volume
- 3
- Issue
- 2
- Pages
- 63???65
- ISSN
- 0195-9131
- Cited by
- 4
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of a continuous and discontinuous graded treadmill test for maximal oxygen uptake. https://app.cochat.ai/papers/10.1249/00005768-197100320-00003
- The paper
- MAKSUD, M. G., & COUTTS, K. D. (1971). Comparison of a continuous and discontinuous graded treadmill test for maximal oxygen uptake. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-197100320-00003