Analysis of the reliability and validity of the kinetic communicator exercise device
Abstract
The Kinetic Communicator (KINCOM), a microcomputer controlled, hydraulically driven device for the test, measurement, and rehabilitation of human joint function, was tested for the reliability and validity of its operating systems. Testing focused on the three primary functions of the KINCOM: lever arm position, lever arm velocity, and force measuring systems. Measurements of the functions were made via external devices and were compared to measurements simultaneously made by the KINCOM system. Tests were performed for both static and dynamic operation of the unit. Force measurements averaged a difference of 3.2% or less, lever arm speed was within 1.5% of the target speed in all cases, and no difference was found in position measurement. These discrepancies were felt to be due to calibration error and were not considered an indication of inaccuracy in the KINCOM system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aagaard, P., Simonsen, E. B., Andersen, J. L., Magnusson, P., & Dyhre-Poulsen, P. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00283.2002 · Cited by 1,844
Hand‐held Dynamometry Correlation With the Gold Standard Isokinetic Dynamometry: A Systematic Review
Stark, T., Walker, B., Phillips, J. K., Fejer, R., & Beck, R. (2011) · PM&R · doi:10.1016/j.pmrj.2010.10.025 · Cited by 816
Aagaard, P., Simonsen, E. B., Andersen, J. L., Magnusson, S. P., Halkjær-Kristensen, J., & Dyhre-Poulsen, P. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.6.2249 · Cited by 419
Tremblay, J. P., Malouin, F., Roy, R., Huard, J., Bouchard, J. P., Satoh, A., & Richards, C. L. (1993) · Cell Transplantation · doi:10.1177/096368979300200203 · Cited by 345
Suetta, C., Aagaard, P., Rosted, A., Jakobsen, A. K., Duus, B., Kjaer, M., & Magnusson, S. P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01307.2003 · Cited by 326
Metadata
- Authors
- FARRELL, M., & RICHARDS, J. G.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1986-02
- Volume
- 18
- Issue
- 1
- Pages
- 44???49
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2072643777
- Cited by
- 229
- References
- 0
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of the reliability and validity of the kinetic communicator exercise device. https://app.cochat.ai/papers/10.1249/00005768-198602000-00009
- The paper
- FARRELL, M., & RICHARDS, J. G. (1986). Analysis of the reliability and validity of the kinetic communicator exercise device. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-198602000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.