The DOI matches its Crossref record.
The Caltrac accelerometer as a physical activity monitor for school-age children
Abstract
The performance of the Caltrac accelerometer was studied in elementary school-age children under field and laboratory conditions. In Study 1, 35 children (20 boys, 15 girls, mean age = 10.8 yr) wore the accelerometer and a heart rate (HR) monitor for 2 d. Caltrac activity counts per hour were compared to the mean "activity HR", which was calculated by subtracting the mean of the five lowest HRs of the day from each recorded HR. Pearson r's between accelerometer and activity HR were 0.54 (P less than 0.001) on day 1 and 0.42 (P less than 0.02) on day 2. Inter-instrument reliability in the field was r = 0.96. Both accelerometer and HR data were significantly correlated with physical activity recalls of the same day. In Study 2, 15 children walked/ran for 10 min at 3, 4, and 5 mph on a horizontal treadmill while wearing two accelerometers. Oxygen uptake was directly measured each minute. Reliability of the Caltracs in the laboratory was 0.89. Activity count correlated r = 0.82 (SEE = 23%) with net calorie cost per kg of body weight. Net caloric expenditure per kg of weight was 0.101 kcal.kg-1.d-1 per Caltrac activity count. These data support the use of the Caltrac accelerometer as a physical activity measure for school-age children, and the objective data tended to corroborate the children's short-term activity recalls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Physical Activity Assessment in Children and Adolescents
Sirard, J. R., & Pate, R. R. (2001) · Sports Medicine · doi:10.2165/00007256-200131060-00004 · Cited by 1,049
CROCKER, P. R. E., BAILEY, D. A., FAULKNER, R. A., KOWALSKI, K. C., & McGRATH, R. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199710000-00011 · Cited by 982
Sallis, J. F., McKenzie, T. L., Alcaraz, J. E., Kolody, B., Faucette, N., & Hovell, M. F. (1997) · American Journal of Public Health · doi:10.2105/ajph.87.8.1328 · Cited by 914
Self-citationBouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Metadata
- Authors
- SALLIS, J. F., BUONO, M. J., ROBY, J. J., CARLSON, D., & NELSON, J. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1990-10
- Volume
- 22
- Issue
- 5
- Pages
- 698-703
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2078915016
- Cited by
- 201
- References
- 0
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Caltrac accelerometer as a physical activity monitor for school-age children. https://app.cochat.ai/papers/10.1249/00005768-199010000-00023
- The paper
- SALLIS, J. F., BUONO, M. J., ROBY, J. J., CARLSON, D., & NELSON, J. A. (1990). The Caltrac accelerometer as a physical activity monitor for school-age children. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199010000-00023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.