Electromechanical delay during knee extensor contractions
The DOI matches its Crossref record.
Abstract
VOS, E. J., J. HARLAAR, and G. J. VAN INGEN SCHENAU. Electromechanical delay during knee extensor contractions. Med. Sci. Sports Exerc., Vol. 23, No. 10, pp. 1187–1193, 1991. The purpose of this study was to investigate the magnitude of electromechanical delay (EMD) and its possible dependence on muscle type, type of contraction, fatigue, level of force, initial muscle length, and muscle contraction velocity. This was achieved using an experiment that measured voluntary knee extensor torques and surface EMG activity for a variety of different contractile conditions in seven male subjects. EMD values were obtained using a cross-correlation technique in three experimental KIN-COM dynamometer conditions of vastus medialis, rectus femoris, and vastus lateralis. In the first condition, a series of 10 repetitive submaximal (50% and 70% MVC) isometric knee extensor contractions were performed at knee angles of 90° and 130° extension. In the second condition, 10 maximal isokinetic knee extensor contractions were performed during passive shortening and lengthening. As such, the dynamometer was used to passively move the knee joint at 30°.s-1 and 60°.s-1. Both during lengthening and shortening, the contractions occurred at an angular position of 110°. In the last condition, a repetitive submaximal isometric knee extensor fatigue test was performed for 100 s (150 contractions). At 10, 40, and 90 s during the time course of this fatigue test, a series of 10 contractions were recorded. To avoid a phase lag, which is introduced with one-way filtering, the EMG was processed with a bidirectional low-pass filter application. A significant main effect in EMD for the factor level of force was found. The EMD values obtained at a force level of 50% MVC were longer than at 70% MVC (107 vs 98 ms). However, no significant main effects in EMD for the factors initial muscle length, type of contraction, fatigue, and muscle contraction velocity were found. In addition, all the EMD values obtained in the three conditions lie in the same range. A mean EMD value (over conditions) of 106 ms in knee extensor muscles was found. Moreover, contraction and relaxation delays were computed and compared with the conditions 1 and 3. There was a significant difference between the contraction and relaxation delays; the mean (over condition 1 and 3) was 107 ms, and the mean (over condition 1 and 3) was 118 ms, respectively. Despite this difference, the computed contraction and relaxation delay values also lie in the same range as the total phase lag, calculated with the cross-correlation technique. Thus, our results suggest that the EMD values obtained under these three exercise conditions behave much like a constant latency. Additionally, the magnitude of EMD values found supports the need to account for this delay when interpreting temporal aspects of patterns of intermuscular coordination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lewek, M., Rudolph, K., Axe, M., & Snyder-Mackler, L. (2002) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00097-3 · Cited by 541
Methodological aspects of SEMG recordings for force estimation – A tutorial and review
Staudenmann, D., Roeleveld, K., Stegeman, D. F., & van Dieën, J. H. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2009.08.005 · Cited by 379
Biomechanics and muscular activity during sit-to-stand transfer
Roebroeck, M. E., Doorenbosch, C. A. M., Harlaar, J., Jacobs, R., & Lankhorst, G. J. (1994) · Clinical Biomechanics · doi:10.1016/0268-0033(94)90004-3 · Cited by 299
Self-citationNeuromuscular Performance of Explosive Power Athletes versus Untrained Individuals
TILLIN, N. A., JIMENEZ-REYES, P., PAIN, M. T. G., & FOLLAND, J. P. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181be9c7e · Cited by 284
“The EMD values recorded in this study (6-15 ms) were relatively low compared to previous studies (14-90 ms, (22, 27, 29, 44, 48, 49, 51)).”
Does Elastic Energy Enhance Work and Efficiency in the Stretch-Shortening Cycle?
Schenau, G. J. V. I., Bobbert, M. F., & de Haan, A. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.4.389 · Cited by 260
Metadata
- Authors
- VOS, E. J., HARLAAR, J., & VAN INGEN SCHENAU, G. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1991-10
- Volume
- 23
- Issue
- 10
- Pages
- 1187???1193
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2046457636
- Cited by
- 133
- References
- 0
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromechanical delay during knee extensor contractions. https://app.cochat.ai/papers/10.1249/00005768-199110000-00013
- The paper
- VOS, E. J., HARLAAR, J., & VAN INGEN SCHENAU, G. J. (1991). Electromechanical delay during knee extensor contractions. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199110000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.