The DOI matches its Crossref record.
The validity of regulating exercise intensity by ratings of perceived exertion
Abstract
The purpose of this investigation was to examine the regulation of exercise intensity by using Ratings of Perceived Exertion (RPE). The RPE equivalent to 50% and 70% VO2max was estimated by using standard clinical protocols on a treadmill and cycle ergometer. Subjects then produced the target RPEs on these modalities. Physiological validity of perceptually regulated exercise intensity was determined by comparing VO2 and heart rate between estimation and production trials at the same relative intensity. With one exception, RPE was found to be a valid means of regulating exercise intensity both intra- and intermodally at 50% and 70% VO2max. Perceptual regulation of intramodal treadmill exercise was not valid at 70% VO2max in that both VO2 and heart rate were significantly lower during production than estimation. The present results also indicate that target RPE estimated during a cycle ergometer graded exercise test is more accurate for regulating exercise intensity than when the target RPE is estimated during a treadmill test. The lower accuracy found for treadmill production at the higher exercise intensity may have been caused by the use of a test protocol during the estimation trial that included relatively slow speeds and large inclines. In general, RPE provide a physiologically valid method of regulating exercise intensity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mezzani, A., Hamm, L. F., Jones, A. M., McBride, P. E., Moholdt, T., Stone, J. A., Urhausen, A., & Williams, M. A. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487312460484 · Cited by 550
Fat adaptation followed by carbohydrate loading compromises high-intensity sprint performance
Havemann, L., West, S. J., Goedecke, J. H., Macdonald, I. A., St Clair Gibson, A., Noakes, T. D., & Lambert, E. V. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00813.2005 · Cited by 165
Colberg, S. R., Swain, D. P., & Vinik, A. I. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.986 · Cited by 109
Chan, A. P. C., Yi, W., Wong, D. P., Yam, M. C. H., & Chan, D. W. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.006 · Cited by 91
Bok, D., Rakovac, M., & Foster, C. (2022) · Sports Medicine · doi:10.1007/s40279-022-01690-3 · Cited by 89
Metadata
- Authors
- DUNBAR, C. C., ROBERTSON, R. J., BAUN, R., BLANDIN, M. F., METZ, K., BURDETT, R., & GOSS, F. L.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1992-01
- Volume
- 24
- Issue
- 1
- Pages
- 94???99
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1990236957
- Cited by
- 281
- References
- 0
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The validity of regulating exercise intensity by ratings of perceived exertion. https://app.cochat.ai/papers/10.1249/00005768-199201000-00016
- The paper
- DUNBAR, C. C., ROBERTSON, R. J., BAUN, R., BLANDIN, M. F., METZ, K., BURDETT, R., & GOSS, F. L. (1992). The validity of regulating exercise intensity by ratings of perceived exertion. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199201000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.