Accuracy of RPE from graded exercise to establish exercise training intensity
The DOI matches its Crossref record.
Abstract
The purpose of this investigation was to examine the accuracy of an exercise intensity prescription based upon perceptual responses obtained during a graded exercise test. Fifteen physically active men completed a graded exercise test (GXT) on a motor driven treadmill. Heart rate (HR), oxygen uptake (VO2), and RPE were measured each minute. An RPE intensity prescription was calculated as 75% of heart rate reserve from the GXT heart rate and RPE data. A minimum of 48 h later the subjects completed 10 min of exercise (EXT) on a level treadmill at the prescribed RPE. The subjects set the treadmill speed to elicit an exercise intensity equal to the prescribed perception of effort. There were significant mean differences (P < 0.05) in heart rate between the GXT (161.8 +/- 1.3) and EXT (154.9 +/- 4.5). However, by minute 6 the subjects were within four beats.min-1 of the target heart rate. There were no significant differences (P > 0.05) between GXT and EXT for VO2 (36.1 +/- 5.2, 33.1 +/- 6.4) and VE (64.1 +/- 10.8, 58.4 +/- 13.5) respectively. The present investigation demonstrates that a subject's perceptual response to a GXT can be used to accurately prescribe exercise intensity during level treadmill running. The intensity selected was within a typical range used for exercise prescription. The advantage of RPE as a method of exercise prescription is that an individual does not need to stop during exercise and measure a heart rate, but can make pace adjustments while exercising based solely upon the perception of effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cerebral perturbations provoked by prolonged exercise
Nybo, L., & Secher, N. H. (2004) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2004.03.005 · Cited by 398
Use and Misuse of the Likert Item Responses and Other Ordinal Measures
Bishop, P. A., & Herron, R. L. (2015) · International Journal of Exercise Science · doi:10.70252/lanz1453 · Cited by 367
Hampson, D. B., Gibson, A. S., Lambert, M. I., & Noakes, T. D. (2001) · Sports Medicine · doi:10.2165/00007256-200131130-00004 · Cited by 297
Use of Ratings of Perceived Exertion in Sports
Eston, R. (2012) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.7.2.175 · Cited by 283
Colberg, S. R., Swain, D. P., & Vinik, A. I. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.986 · Cited by 109
Metadata
- Authors
- GLASS, S. C., KNOWLTON, R. G., & BECQUE, M. D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1992-11
- Volume
- 24
- Issue
- 1
- Pages
- 1303???1307
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2062313339
- Cited by
- 103
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of RPE from graded exercise to establish exercise training intensity. https://app.cochat.ai/papers/10.1249/00005768-199211000-00017
- The paper
- GLASS, S. C., KNOWLTON, R. G., & BECQUE, M. D. (1992). Accuracy of RPE from graded exercise to establish exercise training intensity. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199211000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.