CoChat

Oxygen uptake and heart rate relationship in persons with spinal cord injury

HOOKER, STEVEN P., GREENWOOD, JOHN D., HATAE, DAVID T., HUSSON, ROXANNE P., MATTHIESEN, TRACI L., WATERS, ANTHONY R. · 1993 · Medicine & Science in Sports & Exercise
Cited by 61

The DOI matches its Crossref record.

Abstract

HOOKER, S. P., J. D. GREENWOOD, D. T. HATAE, R. P. HUSSON, T. L. MATTHIESEN, and A. R. WATERS. Oxygen uptake and heart rate relationship in persons with spinal cord injury. Med. Sci. Sports Exerc., Vol. 25, No. 10, pp. 1115–1119, 1993. The percent (%) peak oxygen uptake (VO2) and %peak heart rate (HR) relationships were determined in 13 persons with high (T1-T6) and 14 persons with low lesion (T7-T12) spinal cord injured paraplegia (SCI PARA) and 15 nonimpaired subjects during graded arm crank (AC) tests to exhaustion. Subjects were instructed to maintain a target cadence of 60 rpm on a modified electronically braked leg cycle ergometer. After 3 min of unloaded cranking, power output (PO) was increased by 8–16 W·min−1. VO2 and HR were determined via open-circuit spirometry and 12-lead ECG, respectively. Absolute HR and VO2 values for each PO were converted to %peak HR and %peak VO2 values. Linear regression slopes describing individual %peak HR and %peak VO2 relationships were calculated and compared between groups with one-way ANOVA. No significant differences (P > 0.05) were noted between the mean (± SD) regression slopes for persons with high lesion SCI PARA (1.48 ± 0.21), persons with low lesion SCI PARA (1.48 ± 0.26), and nonimpaired subjects (1.53 ± 0.29). Regression equations derived using all data points within each group were as follows: High lesion SCI PARA: y = 1.31x - 37.0, R = 0.85 Low lesion SCI PARA: y = 1.23x - 30.9, R = 0.88 Nonimpaired subjects: y = 1.41x - 46.2, R = 0.95 (y = %peak VO2, × = %peak HR). These equations are similar to those previously reported for nonimpaired men and women and cardiac patients during AC and leg cycle ergometry. Therefore, the data suggest that already established exercise prescription guidelines need not be modified for persons with high or low lesion SCI PARA and HR can be confidently used as an indicator of AC exercise intensity in these persons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/00005768-199310000-00006

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 61

Metadata

Authors
HOOKER, S. P., GREENWOOD, J. D., HATAE, D. T., HUSSON, R. P., MATTHIESEN, T. L., & WATERS, A. R.
Venue
Medicine & Science in Sports & Exercise
Published
1993-08
Volume
25
Issue
10
Pages
1115???1119
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2051583014
Cited by
61
References
0
FWCI
1.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen uptake and heart rate relationship in persons with spinal cord injury. https://app.cochat.ai/papers/10.1249/00005768-199310000-00006
The paper
HOOKER, S. P., GREENWOOD, J. D., HATAE, D. T., HUSSON, R. P., MATTHIESEN, T. L., & WATERS, A. R. (1993). Oxygen uptake and heart rate relationship in persons with spinal cord injury. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199310000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.