Walking and running energy expenditure estimated by Caltrac and indirect calorimetry
The DOI matches its Crossref record.
Abstract
The purpose of this study was to examine the accuracy of the Caltrac personal activity computer during walking and running. Ten women and 10 men walked at speeds of 2-5 mph and ran at speeds of 4-8 mph on a horizontal treadmill. Two Caltrac monitors were attached over opposite hips: one programed to give caloric expenditure and the other to give Caltrac counts. Oxygen uptake was measured simultaneously. Significant correlations were found during walking between Caltrac estimated and actual energy expenditure (r = 0.91) and between activity counts and net exercise VO2.kg-1 (r = 0.87). However, the Caltrac significantly overestimated energy cost during horizontal walking at speeds above 2 mph. Although there was a significant correlation between Caltrac estimated and actual energy expenditure during running (r = 0.71), the correlation between Caltrac counts and net exercise VO2.kg-1 was not significant (r = 0.29). There was no significant increase in Caltrac kcal or counts with increased running speed between 5 and 8 mph. It is concluded that the Caltrac is a valid indicator of physical activity during walking but does not adequately discriminate between running speeds of 5-8 mph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Reliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Metadata
- Authors
- HAYMES, E. M., & BYRNES, W. C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1993-12
- Volume
- 25
- Issue
- 12
- Pages
- 1365???1369
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2072564356
- Cited by
- 80
- References
- 0
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Walking and running energy expenditure estimated by Caltrac and indirect calorimetry. https://app.cochat.ai/papers/10.1249/00005768-199312000-00008
- The paper
- HAYMES, E. M., & BYRNES, W. C. (1993). Walking and running energy expenditure estimated by Caltrac and indirect calorimetry. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199312000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.