Arterial blood pressure response to rowing
The DOI matches its Crossref record.
Abstract
Ten male oarsmen performed a 6-min bout of "all-out" exercise on a rowing ergometer in the laboratory. Intraarterial blood pressure was recorded from a catheter inserted percutaneously into the radial artery. Mean arterial pressure increased only modestly from 110 +/- 13 to 122 +/- 24 mm Hg (P < 0.05). Large fluctuations in pressure were superimposed on the normal blood pressure waveform during rowing. These rhythmic pressure fluctuations exhibited a one-to-one coupling with stroke rate and were 2-3 times the magnitude of the normal pulse pressure. Thus, the effective pulse pressure during the 1st minute of rowing (112 +/- 11 mm Hg) was markedly higher (P < 0.01) than the pulse pressure at rest (45 +/- 5 mm Hg) and remained so throughout the exercise bout. In five additional subjects in which central venous pressure (CVP) was measured, large stroke-related fluctuations in pressure were also seen in the CVP waveform. Similar fluctuations in blood pressure were observed during repetitive Valsalva maneuvers. These results suggest that the blood pressure response to rowing is principally influenced by a Valsalva-like maneuver performed at the catch of each stroke. The observed arterial pressure fluctuations may explain the degree of myocardial hypertrophy that occurs in the hearts of rowers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Athlete’s Heart: A Meta-Analysis of Cardiac Structure and Function
Pluim, B. M., Zwinderman, A. H., van der Laarse, A., & van der Wall, E. E. (2000) · Circulation · doi:10.1161/01.cir.101.3.336 · Cited by 1,110
Cerebral perturbations provoked by prolonged exercise
Nybo, L., & Secher, N. H. (2004) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2004.03.005 · Cited by 398
“This factor could influence cerebral oxygenation during exercise tasks associated with large fluctuations in blood pressure, including rowing, where the oarsmen perform a Valsalva-like manoeuvre at the catch of each stroke (Clifford et al., 1994).”
BackgroundSelf-citationLevine, B. D., Baggish, A. L., Kovacs, R. J., Link, M. S., Maron, M. S., & Mitchell, J. H. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.09.033 · Cited by 248
Physiological and Biomechanical Aspects of Rowing: Implications for Training
Secher, N. H. (1993) · Sports Medicine · doi:10.2165/00007256-199315010-00004 · Cited by 219
Self-citationLevine, B. D., Baggish, A. L., Kovacs, R. J., Link, M. S., Maron, M. S., & Mitchell, J. H. (2015) · Circulation · doi:10.1161/cir.0000000000000237 · Cited by 170
Metadata
- Authors
- CLIFFORD, P. S., HANEL, B., & SECHER, N. H.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1994-06
- Volume
- 26
- Issue
- 6
- Pages
- 715-719
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2006484652
- Cited by
- 70
- References
- 0
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arterial blood pressure response to rowing. https://app.cochat.ai/papers/10.1249/00005768-199406000-00010
- The paper
- CLIFFORD, P. S., HANEL, B., & SECHER, N. H. (1994). Arterial blood pressure response to rowing. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199406000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.