The DOI matches its Crossref record.
Assessment of energy expenditure for physical activity using a triaxial accelerometer
Open accessAbstract
A triaxial accelerometer was used to evaluate the relationship between energy expenditure due to physical activity (EEact) and body acceleration during different types of activity. In a laboratory experiment, 11 male subjects performed sedentary activities and walked on a motor driven treadmill (3-7 km.h-1). EEact was calculated from total energy expenditure (EEtot), as measured by indirect calorimetry, and sleeping metabolic rate (SMR): EEact = EEtot--SMR. Body accelerations were measured with a triaxial accelerometer at the low back. Special attention was paid to the analysis of unidirectional and three-directional accelerometer output. During sedentary activities a linear relationship between EEact and the sum of the integrals of the absolute value of accelerometer output from all three measurement directions (IAAtot) was found (r = 0.82, P < 0.001, Sy,x = 0.22 W.kg-1). During walking EEact was highly correlated with the integral of absolute accelerometer output in antero-posterior direction (IAAx; r = 0.96, P < 0.001, Sy,x = 0.53 W.kg-1). When all examined activities were included in a regression analysis, a strong linear relationship between EEact and IAAtot was found (r = 0.95, P < 0.001, Sy,x = 0.70 W.kg-1). Using this relationship, EEact during sedentary activities as well as EEact during walking could be estimated with an accuracy of about 15%. Although sedentary activities and walking represent a large part of normal daily physical activity, the validity and usefulness of the triaxial accelerometer--measuring IAAtot--to predict EEact in daily life must be studied under free-living conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Self-citationEston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Metadata
- Authors
- BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1994-12
- Volume
- 26
- Issue
- 12
- Pages
- 1516???1523
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1967571053
- Cited by
- 451
- References
- 0
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of energy expenditure for physical activity using a triaxial accelerometer. https://app.cochat.ai/papers/10.1249/00005768-199412000-00016
- The paper
- BOUTEN, C. V., WESTERTERP, K. R., VERDUIN, M., & JANSSEN, J. D. (1994). Assessment of energy expenditure for physical activity using a triaxial accelerometer. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199412000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.