Estimation of critical power with nonlinear and linear models
The DOI matches its Crossref record.
Abstract
Sixteen young, healthy males each performed five to seven randomly assigned, exhaustive exercise bouts on a cycle ergometer, with each bout on a separate day and at a different power, to compare estimates of critical power (PC) and anaerobic work capacity (W') among five different models: t = W'/(P - PC) (two-parameter nonlinear); t = (W'/(P - PC)) - (W'/(Pmax - PC)) (three-parameter nonlinear); P ± t = W' + (PC't) (linear (P · t)); P = (W'/t) + PC (linear (P)); P = PC + (Pmax - PC)exp(−t/τ) (exponential). The data fit each of the models well (mean R2 = 0.96 through 1.00 for each model). However, significant differences among models were observed for both PC (mean · standard deviation (SD) for each model was 195 ± 29 W through 242 ± 21 W) and W' (18 ± 5 kJ through 58 ± 19 kJ). PC estimates among models were significantly correlated (r = 0.78 through 0.99). For W', between-model correlations ranged from 0.25 to 0.95. For a group of six subjects, the ventilatory threshold for long-term exercise (LTE Tvent; 189 ± 34 W) was significantly lower than PC for all models except the three-parameter nonlinear (PC = 197 ± 30 W); PC for each model was, however, positively correlated with LTE Tvent (r = 0.69 through 0.91). The three-parameter nonlinear model, with t appropriately designated as the dependent variable, is preferred first, on statistical grounds; second, because the assumption is not made that P is infinite as t approaches 0; and third, because it produces a PC estimate that comes closest to a physiological parameter, LTE Tvent, that reflects the capacity for sustained aerobic power output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Muscle metabolic responses to exercise above and below the “critical power” assessed using31P-MRS
Jones, A. M., Wilkerson, D. P., DiMenna, F., Fulford, J., & Poole, D. C. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00731.2007 · Cited by 478
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Billat, V. L., Sirvent, P., Py, G., Koralsztein, J.-P., & Mercier, J. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00003 · Cited by 397
Methods to Determine Aerobic Endurance
Bosquet, L., L??ger, L., & Legros, P. (2002) · Sports Medicine · doi:10.2165/00007256-200232110-00002 · Cited by 279
Metadata
- Authors
- GAESSER, G. A., CARNEVALE, T. J., GARFINKEL, A., WALTER, D. O., & WOMACK, C. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1995-10
- Volume
- 27
- Issue
- 10
- Pages
- 1430???1438
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2091476178
- Cited by
- 138
- References
- 0
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of critical power with nonlinear and linear models. https://app.cochat.ai/papers/10.1249/00005768-199510000-00012
- The paper
- GAESSER, G. A., CARNEVALE, T. J., GARFINKEL, A., WALTER, D. O., & WOMACK, C. J. (1995). Estimation of critical power with nonlinear and linear models. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199510000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.