CoChat

Hydration Testing in Collegiate Wrestlers Undergoing Hypertonic Dehydration

BARTOK, CYNTHIA, SCHOELLER, DALE A., SULLIVAN, JUDE C., CLARK, R. RANDALL, LANDRY, GREGORY L. · 2004 · Medicine & Science in Sports & Exercise
Cited by 76

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Because dehydration (DEH) violates assumptions used in the assessment of body composition, hydration testing has become an integral part of minimal weight (MW) assessment. PURPOSE: To determine the accuracy of hydration tests for the detection and quantification of hypertonic DEH. METHODS: Twenty-five male collegiate wrestlers (mean +/- SD, age: 20.0 +/- 1.4 yr, height: 175.0 +/- 7.1 cm, body mass: 81.7 +/- 15.3 kg) had their hydration assessed under well-controlled conditions of euhydration (EUH) and DEH. The DEH phase occurred on the same day as EUH, after subjects acutely dehydrated 2-6% of body weight through fluid/food restriction and exercise in a hot environment. RESULTS: All hydration tests except plasma potassium significantly increased from EUH to DEH, and meaningful cutoff values could be established for most tests. Cutoff values for urine tests were 586 mOsm.L(-1) for osmolality and 71 mEq.L(-1) for potassium. Plasma cutoff values were 293 mOsm.L(-1) for osmolality, 140 mEq.L(-1) for sodium, 103 mEq.L(-1) for chloride, and 3.5 pg.mL(-1) for arginine vasopressin. For ratio tests, a urine:plasma osmolality of 2.06 and an extracellular:intracellular water of 0.533 measured by the bioelectrical impedance spectroscopy were cutoff values. For urine specific gravity, a cutoff value of 1.020 g.mL(-1) had a sensitivity and specificity of 96% each for the automated harmonic oscillation technique and 87% and 91% (respectively) for the dipstick technique. Protein (by dipstick) was detected in 5% of subjects in EUH, and 100% of subjects in DEH. Correlations between hydration tests and dehydration were only low to moderate. CONCLUSION: This study supports a specific gravity cutoff of 1.020 g.mL(-1) for the identification of hypertonic DEH. Future research should test the cutoff values established in this study and explore the relationship between DEH and urine protein.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000117164.25986.f6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 76

Metadata

Authors
BARTOK, C., SCHOELLER, D. A., SULLIVAN, J. C., CLARK, R. R., & LANDRY, G. L.
Venue
Medicine & Science in Sports & Exercise
Published
2004-03
Volume
36
Issue
3
Pages
510-517
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2075822626
Cited by
76
References
1
FWCI
1.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.