CoChat

Influence of Testing Protocol on Ventilatory Thresholds and Cycling Performance

AMANN, MARKUS, SUBUDHI, ANDREW, FOSTER, CARL · 2004 · Medicine & Science in Sports & Exercise
Cited by 92

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare the ventilatory response of two incremental exercise tests and determine their predictive validity on 40-km cycle time trial (40K) mean power output (40Kavgwatts). METHODS: Fifteen male cyclists performed two incremental exercise tests (T50x3:100 W +50 W x 3(-1) min, T25x1:20 W + 25 W x min(-1)) and a 40K over an 8-d period. Key variable was power at ventilatory threshold (VT). For VT determination during each test we used: VE/VO2 method, first clear breakpoint on the VE/VCO2 plot, V-slope method, RER = 1, and RER = 0.95. RESULTS: VO2max during T50x3 and T25x1 was not different (66.6 vs 67.6 mL x kg(-1) x min(-1)), although T25x1 peak power output (MaxT25x1; 402 W) was significantly higher than MaxT50x3 (363 W). T50x3 and T25x1 VT power outputs indicated that the power output at T25x1:RER = 1 and T25x1:RER = 0.95 were significantly higher compared with T50x3 (324 vs 304 W and 282 vs 264 W, respectively). Regression analyses between T50x3 variables and 40Kavgwatts were significant for T50x3:V-slope (R2 = 0.37; SEE 20.2 W), T50x3:VE/VO2 (R2 = 0.64; SEE 15.3 W), T50x3:RER = 0.95 (R2 = 0.42; SEE 19.4 W), T50x3:RER = 1 (R2 = 0.45; SEE 18.8 W), and MaxT50x3 (R2 = 0.51; SEE 17.8 W). Regression analyses between T25x1 variables and 40Kavgwatts were significant for T25x1:V-slope (R2 = 0.63; SEE 15.4 W), T25x1:VE/VO2 (R2 = 0.64; SEE 15.2 W), T25x1:RER = 0.95 (R2 = 0.53; SEE 17.4 W), T25x1:RER = 1 (R2 = 0.57; SEE 16.7 W), and MaxT25x1 (R2 = 0.65; SEE 15.0 W). There was no significant difference between 40Kavgwatts (282 W) and power outputs at T50x3:VE/VO2 (277 W), T50x3:V-slope (289 W), T25x1:VE/VO2 (276 W), and T25x1:RER = 0.95 (282 W). CONCLUSION: Generally, T25x1 based VT variables were superior to T50x3 variables regarding the prediction of 40Kavgwatts. We conclude that the VE/VO2 method is protocol independent and a valid 40Kavgwatts predictor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000122076.21804.10

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 92

Metadata

Authors
AMANN, M., SUBUDHI, A., & FOSTER, C.
Venue
Medicine & Science in Sports & Exercise
Published
2004-04
Volume
36
Issue
4
Pages
613-622
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2073030997
Cited by
92
References
3
FWCI
3.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Testing Protocol on Ventilatory Thresholds and Cycling Performance. https://app.cochat.ai/papers/10.1249/01.mss.0000122076.21804.10
The paper
AMANN, M., SUBUDHI, A., & FOSTER, C. (2004). Influence of Testing Protocol on Ventilatory Thresholds and Cycling Performance. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000122076.21804.10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.