PURPOSE: To establish the typical error (TE) associated with equipment, testing, and biological variation of a running economy (RE) test in 11 elite male distance runners (VO2max 70.3 +/- 7.3 mL x min(-1) x kg(-1)), and measure the between-athlete variation of 70 highly trained runners (VO2max 69.7 +/- 6.0 mL x min(-1) x kg(-1)) to determine the magnitude of the smallest worthwhile change (SWC) required for RE. METHODS: Runners performed three 4-min bouts of submaximal treadmill running at speeds of 14, 16, and 18 km x h(-1) (0% grade), on two separate occasions within a 7-d period to determine reliability and once over a 3-yr period to measure the SWC. During all RE tests O2 consumption (VO2), ventilation (VE), respiratory exchange ratio (RER), heart rate (HR), stride rate (SR), and concentration of blood lactate (Lac) were determined. RESULTS: The TE for the pooled data of three running speeds (14, 16, and 18 km x h(-1)) was 2.4% for VO2, 7.3% for VE, 27% for Lac, and ranged between 1 and 4% for RER, HR, and SR. CONCLUSIONS: The results demonstrate that although the magnitude of the TE for a submaximal treadmill running protocol of three 4-min work efforts is small (2.4-7.3%) for measures associated with cardiorespiratory parameters, it is three- to fourfold higher for Lac. Given the small TE associated with RE, and a SWC of similar magnitude for this cohort of distance runners, the RE test is useful in detecting changes attributable to training interventions. Changes in RE greater than approximately 2.4% in this cohort of elite distance runners are likely to be "real" and "worthwhile," and not simply related to testing error and typical variation.

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000145468.17329.9f

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 26 · Cited by 227

Authors
SAUNDERS, P. U., PYNE, D. B., TELFORD, R. D., & HAWLEY, J. A.
Affiliations
  • Australian Sports Commission (AU)
  • RMIT University (AU)
Venue
Medicine & Science in Sports & Exercise
Published
2004-11
Volume
36
Issue
11
Pages
1972-1976
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2021171217
Cited by
227
References
26
Citations by year
2026: 7 · 2025: 17 · 2024: 12 · 2023: 7 · 2022: 11 · 2021: 11 · 2020: 17 · 2019: 14 · 2018: 11 · 2017: 11 · 2016: 13 · 2015: 13 · 2014: 10 · 2013: 17 · 2012: 9
FWCI
5.19
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • RMIT Research Repository (RMIT University Library) (submittedVersion)
  • Figshare (submittedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
Keywords
running economy, test-retest reliability, typical error, smallest worthwhile change, elite distance runners, blood lactate, VO2, ventilation, respiratory exchange ratio, heart rate, cadence, biological variation
MeSH terms
Adult, Exercise Test, Humans, Male, Oxygen Consumption, Physical Education and Training, Reference Values, Running, Sports Medicine, Reproducibility of Results, Lactic Acid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review