CoChat

SHOULD TIME TRIAL PERFORMANCE BE PREDICTED FROM THREE SERIAL TIME-TO-EXHAUSTION TESTS?

Jeukendrup, Asker E., Currell, Kevin · 2005 · Medicine & Science in Sports & Exercise
Cited by 30

The DOI matches its Crossref record.

Abstract

Dear Editor-in-Chief: Hinckson and Hopkins (1) attempt to convince the reader that time to exhaustion (TTE) is a reliable measure of endurance performance on the basis of predictions of time trial times from three serial runs to exhaustion by means of mathematical modeling. We maintain that the conclusions have been applied beyond the scope of the data that have been collected. Hinckson and Hopkins (1) correctly comment that TTE has traditionally been used as an indicator of endurance performance, but that more recently there has been a shift toward the use of time trial protocols. This change was probably triggered by a paper, published in Medicine & Science in Sport & Exercise® in 1996 (2). In this paper, it was clearly demonstrated that time trials (TT) have less day-to-day variation than TTE protocols, although TTE may be more appropriate in some conditions depending on the research question. In their introduction the authors (1) focus on endurance exercise and they specifically quote the work of Maughan and colleagues, who generally employed TTE tests lasting 40–180 min. However, the study performed by Hinckson and Hopkins (1) does not focus on this duration of exercise, since they purposely restricted TTE to less than 10 min. The study conclusions become even more questionable when one scrutinizes the data more closely. There is an increase in the coefficient of variation for time to exhaustion as the test becomes longer (9.2% for 1.8 min and 16% for 7.8 min). It would be interesting to know what the variation is for TTE tests, which are in the typical “endurance exercise” range. Therefore, irrespective of the outcome of their study, it is problematic to extrapolate their results to exercise of longer duration. We agree with Hinckson and Hopkins (1) that a reliable test (i.e., time trial) does not necessarily mean that differences due to some intervention can be detetcted with this test. On the other hand a test with a large day-to-day variation does not exclude that differences can be detected as a result of an intervention. However, this issue of sensitivity or signal-to-noise ratio was not directly addressed in their study. In order to study the sensitivity of a test the intraindividual variation (noise) as well as the performance effect size (signal) should have been measured for both a TTE test and a TT. In many cases, time trials will be the preferred choice of test because they have greater logical validity. Pacing strategy is an inherent component of real performance rather than something that should be omitted from a performance test. Perhaps most importantly, it seems impractical and illogical to perform two or three separate tests to predict performance with mathematical modeling if it can also be measured directly. The key to a good performance test is the signal-to-noise ratio. If the signal does not exceed the noise it is impossible to pick up differences as a result of an intervention. It is this sensitivity issue that should receive more attention in future studies. Asker E. Jeukendrup Kevin Currell School of Sport and Exercise Sciences University of Birmingham Birmingham, United Kingdom

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000175095.56646.4b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 30

Metadata

Authors
Jeukendrup, A. E., & Currell, K.
Venue
Medicine & Science in Sports & Exercise
Published
2005-10
Volume
37
Issue
10
Pages
1820
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2016083611
Cited by
30
References
0
FWCI
1.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: SHOULD TIME TRIAL PERFORMANCE BE PREDICTED FROM THREE SERIAL TIME-TO-EXHAUSTION TESTS? https://app.cochat.ai/papers/10.1249/01.mss.0000175095.56646.4b
The paper
Jeukendrup, A. E., & Currell, K. (2005). SHOULD TIME TRIAL PERFORMANCE BE PREDICTED FROM THREE SERIAL TIME-TO-EXHAUSTION TESTS? Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000175095.56646.4b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.