Pulmonary O2 Uptake during Exercise: Conflating Muscular and Cardiovascular Responses
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
For moderate-intensity exercise (below lactate threshold, thetaL), muscle O(2) consumption (VO(2)) kinetics are expressed in a first-order phase 2 (or fundamental) pulmonary O(2) uptake (VO(2)) response: dVO(2)/dt . tau + DeltaVO(2)((t)) = DeltaVO(2)((ss)); where DeltaVO(2)(ss) is the steady-state VO(2) increment, and tau the VO(2) time constant (which is within approximately 10% of tauQVO(2)). A likely source of VO(2) control in this intensity domain is ADP-mediated, for which intramuscular phosphocreatine (PCr) may serve as a proxy variable. Whether, in reality, this behavior reflects the operation of a single homogeneous compartment is unclear, however; a multicompartment structure comprised of units having a similar DeltaVO(2)((ss)) but with widely varying tau can also yield a "well-fit" exponential response with an apparent single tau. In support of this is the inverse (although poorly predictive) correlation between tau and both theta(L) and VO(2max). Above theta(L), the fundamental VO(2) kinetics are supplemented with a delayed, slowly developing component that can set VO(2) on a trajectory towards VO(2max), and that has complex temporal- and intensity-related kinetics. This VO(2) slow component is also demonstrable in [PCr], suggesting that the decreased efficiency above theta(L) predominantly reflects a high phosphate cost of force production rather than a high O(2) cost of phosphate production. In addition, the oxygen deficit for the slow component is more likely to reflect a progressive shifting of DeltaVO(2)((ss)) rather than a single DeltaVO(2)((ss)) having a single tau.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxygen Uptake Kinetics in Sport, Exercise and Medicine
Jones, A. M., & Poole, D. C. (2013) · doi:10.4324/9780203613771 · Cited by 342
Modulation of muscle and pulmonary O2 uptakes by circulatory dynamics during exercise
Barstow, T. J., Lamarra, N., & Whipp, B. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.979 · Cited by 257
Self-citationMahler, M. (1985) · The Journal of general physiology · doi:10.1085/jgp.86.1.135 · Cited by 234
Jones, A. M., Wilkerson, D. P., Koppo, K., Wilmshurst, S., & Campbell, I. T. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.045799 · Cited by 94
Cited by
Mezzani, A., Hamm, L. F., Jones, A. M., McBride, P. E., Moholdt, T., Stone, J. A., Urhausen, A., & Williams, M. A. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487312460484 · Cited by 550
“This intensity domain comprises all the WRs above CP that cause VO2 to reach its peak value with no steady-state attainment.(10,11) For the very highest WRs in this intensity domain no VO2 slow component is evident and VO2 may rise with a close to mono-exponential profile that is truncated at peak VO2.”
BackgroundOxygen uptake kinetics as a determinant of sports performance
Burnley, M., & Jones, A. M. (2007) · European Journal of Sport Science · doi:10.1080/17461390701456148 · Cited by 467
Mezzani, A., Agostoni, P., Cohen-Solal, A., Corrà, U., Jegier, A., Kouidi, E., Mazic, S., Meurin, P., Piepoli, M., Simon, A., et al. (2009) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e32832914c8 · Cited by 402
Exercise: Kinetic Considerations for Gas Exchange
Rossiter, H. B. (2010) · Comprehensive Physiology · doi:10.1002/cphy.c090010 · Cited by 231
Self-citationExercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Metadata
- Authors
- WHIPP, B. J., WARD, S. A., & ROSSITER, H. B.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-09
- Volume
- 37
- Issue
- 9
- Pages
- 1574-1585
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2034418129
- Cited by
- 137
- References
- 4
- FWCI
- 10.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.