CoChat

Low Reproducibility Of Lactate Markers During Incremental Cycle Exercise: 1507 Board #109 May 27 11:00 AM - 12:30 PM

Morton, R. Hugh, Stannard, Stephen R., Kay, Bartholomew · 2009 · Medicine & Science in Sports & Exercise
Cited by 120

The DOI matches its Crossref record.

Abstract

PURPOSE: Previous reports on reproducibility of lactate markers during incremental exercise have usually considered only two trials, and these predominantly in running. This study was undertaken to determine the reproducibility of power output at four different markers in a group of subjects over at least six repeated incremental cycling trials held under tightly controlled conditions. METHODS: Ten subjects undertook six, and an eleventh undertook seven, repeated incremental exercises (50W start, +50W every 3-min to volitional exhaustion) on a cycle ergometer. At each trial blood lactate concentration was determined at rest and within the final 30s of each 3-min workload. The Rest+1 and 4.0 mMol.L-1 markers were determined by interpolation, and the blood lactate vs. power output relationship was modelled using a quadratic function, from which the nadir (lactate minimum) and D-max markers were determined. Analyses of variance were utilised to partition inter- and intra-subject variation in power output at these markers. Intraclass correlation coefficients were evaluated to assess reproducibility. Standard calculations were performed for assessment of statistical power. RESULTS: Power output at all markers differed significantly between subjects, but not between trials. Intraclass correlation coefficients were 0.799 for the Rest+1 point, 0.903 for D-max, 0.677 for the nadir, and 0.807 for the 4.0 mMol.L-1 point. Standard errors of measurement were 11.9, 2.5, 9.2 and 9.1 W respectively. Corresponding pooled within-subject standard deviation estimates were 26.1, 7.9, 16.2 and 20.8 W, yielding 95% confidence intervals of width 105.2, 31.8, 65.3 and 83.8 W respectively. At a significance level of 0.05 the calculated powers of detecting a 30 W increment in these markers are 0.31, 0.98, 0.58 and 0.42 respectively. CONCLUSIONS: These results suggest that during incremental cycling exercise the reproducibility of power output at lactate markers other than D-max are not as good as those previously reported for running. In addition, apart from D-max, their error margins are of such magnitude that in trained subjects only gross changes in training status can be identified with significant power.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000354672.52521.40

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 120

Metadata

Authors
Morton, R. H., Stannard, S. R., & Kay, B.
Venue
Medicine & Science in Sports & Exercise
Published
2009-05
Volume
41
Issue
5
Pages
35
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2074716992
Cited by
120
References
0
FWCI
19.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low Reproducibility Of Lactate Markers During Incremental Cycle Exercise: 1507 Board #109 May 27 11:00 AM - 12:30 PM. https://app.cochat.ai/papers/10.1249/01.mss.0000354672.52521.40
The paper
Morton, R. H., Stannard, S. R., & Kay, B. (2009). Low Reproducibility Of Lactate Markers During Incremental Cycle Exercise: 1507 Board #109 May 27 11:00 AM - 12:30 PM. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000354672.52521.40

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.