CoChat

Predicting Human Movement with Multiple Accelerometers Using Movelets

Open access
HE, BING, BAI, JIAWEI, ZIPUNNIKOV, VADIM V., KOSTER, ANNEMARIE, CASEROTTI, PAOLO, LANGE-MAIA, BRITTNEY, GLYNN, NANCY W., HARRIS, TAMARA B., CRAINICEANU, CIPRIAN M. · 2014 · Medicine & Science in Sports & Exercise
Cited by 40

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: The study aims were 1) to develop transparent algorithms that use short segments of training data for predicting activity types and 2) to compare the prediction performance of the proposed algorithms using single accelerometers and multiple accelerometers. METHODS: Sixteen participants (age, 80.6 yr (4.8 yr); body mass index, 26.1 kg·m (2.5 kg·m)) performed 15 lifestyle activities in the laboratory, each wearing three accelerometers at the right hip and left and right wrists. Triaxial accelerometry data were collected at 80 Hz using ActiGraph GT3X+. Prediction algorithms were developed, which, instead of extracting features, build activity-specific dictionaries composed of short signal segments called movelets. Three alternative approaches were proposed to integrate the information from the multiple accelerometers. RESULTS: With at most several seconds of training data per activity, the prediction accuracy at the second-level temporal resolution was very high for lying, standing, normal/fast walking, and standing up from a chair (the median prediction accuracy ranged from 88.2% to 99.9% on the basis of the single-accelerometer movelet approach). For these activities, wrist-worn accelerometers performed almost as well as hip-worn accelerometers (the median difference in accuracy between wrist and hip ranged from -2.7% to 5.8%). Modest improvements in prediction accuracy were achieved by integrating information from multiple accelerometers. DISCUSSION AND CONCLUSIONS: It is possible to achieve high prediction accuracy at the second-level temporal resolution with very limited training data. To increase prediction accuracy from the simultaneous use of multiple accelerometers, a careful selection of integrative approaches is required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000000285

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 40

Metadata

Authors
HE, B., BAI, J., ZIPUNNIKOV, V. V., KOSTER, A., CASEROTTI, P., LANGE-MAIA, B., GLYNN, N. W., HARRIS, T. B., & CRAINICEANU, C. M.
Venue
Medicine & Science in Sports & Exercise
Published
2014-09
Volume
46
Issue
9
Pages
1859-1866
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2314386516
Cited by
40
References
4
FWCI
4.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predicting Human Movement with Multiple Accelerometers Using Movelets. https://app.cochat.ai/papers/10.1249/mss.0000000000000285
The paper
HE, B., BAI, J., ZIPUNNIKOV, V. V., KOSTER, A., CASEROTTI, P., LANGE-MAIA, B., GLYNN, N. W., HARRIS, T. B., & CRAINICEANU, C. M. (2014). Predicting Human Movement with Multiple Accelerometers Using Movelets. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000000285

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.