The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Generating ActiGraph counts from raw acceleration recorded by an alternative monitor.
Open accessAbstract
PURPOSE: This study aimed to implement an aggregation method in Matlab for generating ActiGraph counts from raw acceleration recorded with an alternative accelerometer device and to investigate the validity of the method. METHODS: The aggregation method, including the frequency band-pass filter, was implemented and optimized based on standardized sinusoidal acceleration signals generated in Matlab and processed in the ActiLife software. Evaluating the validity of the aggregation method was approached using a mechanical setup and with a 24-h free-living recording using a convenient sample of nine subjects. Counts generated with the aggregation method applied to Axivity AX3 raw acceleration data were compared with counts generated with ActiLife from ActiGraph GT3X+ data. RESULTS: An optimal band-pass filter was fitted resulting in a root-mean-square error of 25.7 counts per 10 s and mean absolute error of 15.0 counts per second across the full frequency range. The mechanical evaluation of the proposed aggregation method resulted in an absolute mean ± SD difference of -0.11 ± 0.97 counts per 10 s across all rotational frequencies compared with the original ActiGraph method. Applying the aggregation method to the 24-h free-living recordings resulted in an epoch level bias ranging from -16.2 to 0.9 counts per 10 s, a relative difference in the averaged physical activity (counts per minute) ranging from -0.5% to 4.7% with a group mean ± SD of 2.2% ± 1.7%, and a Cohen's kappa of 0.945, indicating almost a perfect agreement in the intensity classification. CONCLUSION: The proposed band-pass filter and aggregation method is highly valid for generating ActiGraph counts from raw acceleration data recorded with alternative devices. It would facilitate comparability between studies using different devices collecting raw acceleration data.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Wearable cameras that take regular photographs offer a suitable alternative25,26 but have not yet been used in sleep studies.”
From Screen Use at Bedtime and Sleep Duration and Quality Among Youths (2024) · cites this paper as [25]
In the citing paper
“Furthermore, although several observational studies used wearable image cameras to describe screen time,25,26,39,40 they did not investigate associations with sleep outcomes.”
From Screen Use at Bedtime and Sleep Duration and Quality Among Youths (2024) · cites this paper as [25]
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Lee, P. H., Macfarlane, D. J., Lam, T., & Stewart, S. M. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-115 · Cited by 3,370
Andersen, L. B., Harro, M., Sardinha, L. B., Froberg, K., Ekelund, U., Brage, S., & Anderssen, S. A. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69075-2 · Cited by 1,518
Self-citationMeasurement of Observer Agreement
Kundel, H. L., & Polansky, M. (2003) · Radiology · doi:10.1148/radiol.2282011860 · Cited by 1,486
Bouten, C. V. C., Koekkoek, K. K., Verduin, M., Kodde, R., & Janssen, J. J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911
Physical Activity Questionnaires for Adults
van Poppel, M. N. M., Chinapaw, M. J. M., Mokkink, L. B., van Mechelen, W., & Terwee, C. B. (2010) · Sports Medicine · doi:10.2165/11531930-000000000-00000 · Cited by 718
van Hees, V. T., Fang, Z., Langford, J., Assah, F. K., Mohammad, A., Crochemore‐Silva, I., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 708
ActiGraph and Actical Physical Activity Monitors
John, D., & Freedson, P. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399f5e · Cited by 353
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
Brage, S., Wedderkopp, N., Franks, P. W., Andersen, L. B., & Froberg, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 352
Self-citationVähä‐Ypyä, H., Vasankari, T. J., Husu, P., Suni, J. H., & Sievänen, H. T. (2014) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12127 · Cited by 247
Comparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 186
Fully proportional actigraphy: A new instrument
Tryon, W. W., & Williams, R. E. (1996) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03200519 · Cited by 181
Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts
Brønd, J. C., & Arvidsson, D. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00628.2015 · Cited by 148
Self-citationMechanical and free living comparisons of four generations of the Actigraph activity monitor
Ried‐Larsen, M., Brønd, J. C., Brage, S., Hansen, B. H., Grydeland, M., Andersen, L. B., & Møller, N. C. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-113 · Cited by 110
Self-citationAccelerometer data reduction in adolescents: effects on sample retention and bias
Toftager, M., Kristensen, P. L., Oliver, M., Duncan, S., Christiansen, L. B., Boyle, E., Brønd, J. C., & Troelsen, J. (2013) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-10-140 · Cited by 99
Self-citationComparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors
John, D., Sasaki, J. E., STAUDENMAYER, J. W., Mavilia, M. G., & Freedson, P. S. (2013) · Sensors · doi:10.3390/s131114754 · Cited by 71
Biomechanical examination of the ‘plateau phenomenon’ in ActiGraph vertical activity counts
John, D., Miller, R. H., Keadle, S. K., Caldwell, G. E., & Freedson, P. S. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/219 · Cited by 66
Comparison of two different physical activity monitors
Paul, D. R., Kramer, M., Moshfegh, A. J., Baer, D. J., & Rumpler, W. V. (2007) · BMC Medical Research Methodology · doi:10.1186/1471-2288-7-26 · Cited by 49
A method to compare new and traditional accelerometry data in physical activity monitoring
van Hees, V. T., Pias, M. R., Taherian, S., Ekelund, U., & Brage, S. (2010) · IEEE International Symposium on a World of Wireless, Mobile and Multimedia Networks (WoWMoM) · doi:10.1109/wowmom.2010.5534986 · Cited by 43
Translation equations to compare ActiGraph GT3X and Actical accelerometers activity counts
Straker, L. M., & Campbell, A. (2012) · BMC Medical Research Methodology · doi:10.1186/1471-2288-12-54 · Cited by 33
Exploring the ActiLife®filtration algorithm: converting raw acceleration data to counts
Peach, D., Hoomissen, J. V., & Callender, H. L. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/12/2359 · Cited by 30
Guinhouya, C. B., Hubert, H., Dupont, G., & Durocher, A. (2005) · Europe PMC (PubMed Central) · Cited by 11
Intergeneration accelerometer differences and correction for on-board frequency-based filtering
Brage, S., van Hees, V. T., & Brage, N. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00019.2009 · Cited by 5
Cited by
Sorted by citations
Measurement of physical activity in clinical practice using accelerometers
Arvidsson, D., Fridolfsson, J., & Börjesson, M. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12908 · Cited by 269
Self-citationAn Open-Source Monitor-Independent Movement Summary for Accelerometer Data Processing
John, D., Tang, Q., Albinali, F., & Intille, S. S. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0068 · Cited by 227
Quantification of acceleration as activity counts in ActiGraph wearable
Neishabouri, A., Nguyen, J., Samuelsson, J. G., Guthrie, T., Biggs, M., Wyatt, J., Cross, D., Karas, M., Migueles, J. H., Khan, S., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-16003-x · Cited by 185
Pedersen, J., Rasmussen, M. G. B., Sørensen, S. O., Mortensen, S. R., Olesen, L. G., Brønd, J. C., Brage, S., Kristensen, P. L., & Grøntved, A. (2022) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2022.1519 · Cited by 79
Self-citationWearable Sensors to Monitor, Enable Feedback, and Measure Outcomes of Activity and Practice
Dobkin, B. H., & Martinez, C. A. (2018) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-018-0896-5 · Cited by 79
Metadata
- Authors
- BRØND, J. C., ANDERSEN, L. B., & ARVIDSSON, D.
- Affiliations
- University of Southern Denmark (DK)
- Western Norway University of Applied Sciences (NO)
- Lund University (SE)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2017-11
- Volume
- 49
- Issue
- 11
- Pages
- 2351-2360
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2621707983
- Cited by
- 166
- References
- 26
- Citations by year
- 2026: 7 · 2025: 18 · 2024: 34 · 2023: 22 · 2022: 26 · 2021: 27 · 2020: 12 · 2019: 14 · 2018: 6
- FWCI
- 6.67
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- cc-by-nc
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, cc-by-nc)
- Lund University Publications (Lund University) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, other-oa)
- Funders
- Vetenskapsrådet
- Syddansk Universitet
- Forskningsrådet om Hälsa, Arbetsliv och Välfärd ((COFAS‐2, 2013‐2716))
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- bandpass filtering, physical activity monitoring, ActiGraph GT3X+, physical activity intensity classification
- MeSH terms
- Acceleration, Female, Humans, Male, Software, Reproducibility of Results, Exercise, Young Adult, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review