Vastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to investigate, in heavy-resistance strength-trained (N = 10) and untrained (N = 10) subjects, the vastus lateralis muscle oxyhemoglobin (O2Hb) desaturation time course in response to a brief, maximal, voluntary isometric contraction. METHODS: The two groups were not statistically different physically. Mean (+/- SD) age, height, and body mass of all the subjects were 28.0 +/- 6.3 yr, 1.8 +/- 0.1 m, and 77.8 +/- 9.9 kg, respectively. Each subject performed five trials. Every trial consisted of 1) a 1-min rest period, 2) a leg press exercise of 2-4 s, and 3) a 5-min recovery period. Leg press exercise consisted of a static maximal voluntary contraction performed using the dominant leg only. Leg press strength was recorded using a load cell. Muscle O2Hb saturation (SmO2) was measured noninvasively by near-infrared spectroscopy (0.17-s sampling time). RESULTS: Rate of force development was higher in the trained subjects than in the untrained ones (6897 +/- 1654 vs 5515 +/- 1434 N x s(-1); P < 0.05). Once the exercise began, the time to the onset of SmO2 decrease was consistently shorter in the untrained than in the trained subjects (2.81 +/- 0.40 vs 3.91 +/- 0.67 s, P < 0.01). In all the trained subjects and in two of the untrained ones, SmO2 started to decrease once the exercise was stopped. After the end of the exercise, SmO2 transiently decreased and reached its minimum value in 15.0 +/- 3.8 and 10.1 +/- 1.3 s in the trained and untrained subjects, respectively (P < 0.01). CONCLUSION: These data suggest that the vastus lateralis muscle of heavy-resistance strength-trained subjects could have a late activation of the oxidative metabolic system, or greater stored oxygen available, during a very fast, short, isometric maximal contraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Aagaard, P., Simonsen, E. B., Andersen, J. L., Magnusson, P., & Dyhre-Poulsen, P. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00283.2002 · Cited by 1,844
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationAndersen, L. L., & Aagaard, P. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0070-z · Cited by 657
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Tarnopolsky, M. A., Rennie, C. D., Robertshaw, H. A., Fedak-Tarnopolsky, S. N., Devries, M. C., & Hamadeh, M. J. (2007) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00472.2006 · Cited by 457
Suetta, C., Aagaard, P., Rosted, A., Jakobsen, A. K., Duus, B., Kjaer, M., & Magnusson, S. P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01307.2003 · Cited by 326
Concurrent Strength and Endurance Training: A Review
Leveritt, M., Abernethy, P. J., Barry, B. K., & Logan, P. A. (1999) · Sports Medicine · doi:10.2165/00007256-199928060-00004 · Cited by 319
The relationship between maximum isometric strength and intramuscular circulatory occlusion
BARNES, W. S. (1980) · Ergonomics · doi:10.1080/00140138008924748 · Cited by 200
Cited by
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Self-citationMuthalib, M., Millet, G. Y., Quaresima, V., & Nosaka, K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309746 · Cited by 71
Self-citationAsymmetry of quadriceps muscle oxygenation during elite short-track speed skating
HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f8942 · Cited by 63
“SRS-derived measure of tissue oxygen saturation measured by the transportable tissue oximeters made by Hamamatsu Photonics Japan (5,6).”
BackgroundMethodKlusiewicz, A., Rębiś, K., Ozimek, M., & Czaplicki, A. (2021) · Biology of Sport · doi:10.5114/biolsport.2021.103571 · Cited by 24
Rębiś, K., Sadowska, D., Starczewski, M., & Klusiewicz, A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.809864 · Cited by 12
Metadata
- Authors
- CETTOLO, V., FERRARI, M., BIASINI, V., & QUARESIMA, V.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2007-11
- Volume
- 39
- Issue
- 11
- Pages
- 1949-1959
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2013569177
- Cited by
- 40
- References
- 13
- FWCI
- 7.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction. https://app.cochat.ai/papers/10.1249/mss.0b013e3181453476
- The paper
- CETTOLO, V., FERRARI, M., BIASINI, V., & QUARESIMA, V. (2007). Vastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3181453476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.