CoChat

Similar Sensitivity of Time to Exhaustion and Time-Trial Time to Changes in Endurance

AMANN, MARKUS, HOPKINS, WILLIAM G., MARCORA, SAMUELE M. · 2008 · Medicine & Science in Sports & Exercise
Cited by 115

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: There is widespread misunderstanding about the ability of constant-power tests to quantify changes in endurance performance. We have therefore compared the sensitivity of a constant-power test with that of a time trial for the effects of arterial oxygenation on endurance performance. METHODS: Eight cyclists performed three constant-power rides to exhaustion and three 5-km time trials on a cycle ergometer in conditions of normoxia, hypoxia, and hyperoxia. After logarithmic transformation of performance times, sensitivity was calculated as the mean change in time divided by the error of measurement derived from the standard deviation of change scores. RESULTS: In normoxia, performance times were 488 +/- 77 s for the constant-power test and 454 +/- 16 s (mean +/- SD) for the time trial. The mean and standard deviation of the change in performance time from normoxia to hypoxia were much larger in the constant-power test (-45% +/- 13%) than in the time trial (5.7% +/- 1.6%); there was a similar disparity in the change from normoxia to hyperoxia (123% +/- 37% and -4.1% +/- 1.4%, respectively). However, sensitivity for the normoxia-hypoxia change in performance in the constant-power test (6.3, 90% confidence interval 4.3-11.4) was similar to that in the time trial (4.5, 3.0-8.2); sensitivities were also similar for the normoxia-hyperoxia changes (3.2, 2.1-6.0; 3.8, 2.5-6.9, respectively). P values for mean performance changes (range, 0.0002-0.000002) reflected these sensitivities. CONCLUSIONS: Time to exhaustion has sensitivity similar to that of time-trial time for the effects of arterial oxygenation and presumably other factors affecting endurance performance. Sensitivity need not be a concern when using constant-power tests to quantify changes in endurance performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31815e728f

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 115

Metadata

Authors
AMANN, M., HOPKINS, W. G., & MARCORA, S. M.
Venue
Medicine & Science in Sports & Exercise
Published
2008-03
Volume
40
Issue
3
Pages
574-578
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2023670511
Cited by
115
References
2
FWCI
6.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Similar Sensitivity of Time to Exhaustion and Time-Trial Time to Changes in Endurance. https://app.cochat.ai/papers/10.1249/mss.0b013e31815e728f
The paper
AMANN, M., HOPKINS, W. G., & MARCORA, S. M. (2008). Similar Sensitivity of Time to Exhaustion and Time-Trial Time to Changes in Endurance. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e31815e728f

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.