Validity and Reliability of Short-Term Heart-Rate Variability from the Polar S810
Open accessAbstract
PURPOSE: : To assess the validity and the reliability of short-term resting heart-rate variability (HRV) measures obtained using the Polar S810 heart-rate monitor and accompanying software. METHODS: : Measures of HRV were obtained from 5-min R to R wave (RR) interval data for 19 males and 14 females during 10 min of quiet rest on three separate occasions at 1-wk intervals using the Polar S810. Criterion measures of HRV were obtained simultaneously using the CardioPerfect (CP; Medical Graphics Corporation, St Paul, MN) 12-lead ECG module. Measures of validity of the Polar S810 were estimated by regression analysis, and measures of reliability of both devices were estimated by analysis of change scores. Measures of the SD of normal-to-normal intervals (SDNN), the root mean square of successive differences (RMSSD), and the low-frequency (LF) and the high-frequency (HF) spectral power and their ratio (LF/HF) were analyzed after log transformation, whereas mean RR and LF and HF in normalized units were analyzed without transformation. RESULTS: : There were marginal differences between the Polar and the CP mean measures of HRV, and the uncertainty in the differences was small. The Polar S810 demonstrated high correlations (0.85-0.99) with CP for all measures of HRV indicating good to near-perfect validity. Except for the low- and the high-frequency normalized units, Polar S810 did not add any substantial technical error to the within-subject variability in the repeated measurements of HRV. CONCLUSION: : HRV measures obtained with the Polar S810 and accompanying software have no appreciable bias or additional random error in comparison with criterion measures, but the measures are inherently unreliable over a 1-wk interval. Reliability of HRV from longer (e.g., 10 min) and/or consecutive 5-min RR recordings needs to be investigated with the Polar and criterion instruments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Polar T31 transmitter monitor (Polar Electro, Kempele, Finland) was used as the criterion measure of heart rate as it is a validated and reliable measure for heart rate compared with 12-lead ECG (electrocardiogram) [27].”
From Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices (2017) · cites this paper as [27]
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,817
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
La Rovere, M. T., Pinna, G. D., Maestri, R., Mortara, A., Capomolla, S., Febo, O., Ferrari, R., Franchini, M., Gnemmi, M., Opasich, C., et al. (2003) · Circulation · doi:10.1161/01.cir.0000047275.25795.17 · Cited by 917
Prediction of functional aerobic capacity without exercise testing
Jackson, A. S., Blair, S. N., Mahar, M. T., Wier, L. T., Ross, R., & STUTEVILLE, J. E. (1990) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199012000-00021 · Cited by 649
Validity of the Polar S810 Heart Rate Monitor to Measure R-R Intervals at Rest
Gamelin, F.-X., Berthoin, S., & Bosquet, L. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218135.79476.9c · Cited by 502
Flagged first, then by citations
Cited by
Sorted by citations
Items 301–302 of 302
The Physiological Effects of a Cross Country Bike Ride on Novice Cyclists
Weatherholt, W. T. (2015) · TopSCHOLAR (Western Kentucky University)
Metadata
- Authors
- NUNAN, D., DONOVAN, G., JAKOVLJEVIC, D. G., HODGES, L. D., SANDERCOCK, G. R. H., & BRODIE, D. A.
- Affiliations
- Buckinghamshire New University (GB)
- University of Bedfordshire (GB)
- University of Essex (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2009-01
- Volume
- 41
- Issue
- 1
- Pages
- 243-250
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2014229115
- Cited by
- 302
- References
- 44
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 14 · 2023: 8 · 2022: 21 · 2021: 19 · 2020: 16 · 2019: 18 · 2018: 24 · 2017: 18 · 2016: 23 · 2015: 21 · 2014: 30 · 2013: 22 · 2012: 22
- FWCI
- 9.95
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Bucks New University Repository (Bucks New University) (submittedVersion)
- Open Access at Essex (University of Essex) (submittedVersion)
- Newcastle University ePrints (Newcastle Univesity)
- Funders
- Medical Research Council (MC_G0802536)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- heart rate variability, heart rate monitors, device validity, test-retest reliability, RR interval, spectral power, within-person variability, resting heart rate
- MeSH terms
- Adult, Algorithms, Female, Heart Rate, Humans, Male, Middle Aged, Surveys and Questionnaires, Regression Analysis, Software, Time Factors, Reproducibility of Results, Electrocardiography, Ambulatory, Confidence Intervals
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review