Comparison of Four ActiGraph Accelerometers during Walking and Running

Open access
JOHN, DINESH, TYO, BRIAN, BASSETT, DAVID R. · 2010 · Medicine & Science in Sports & Exercise

Abstract

UNLABELLED: Currently, researchers can use the ActiGraph 7164 or one of three different versions of the ActiGraph GT1M to objectively measure physical activity. PURPOSE: To determine whether differences exist between activity counts from the ActiGraph 7164 and the three versions of the GT1M at given walking and running speeds. METHODS: Ten male participants (23.6 +/- 2.7 yr) completed treadmill walking and running at 10 different speeds (3-min stages) while wearing the ActiGraph 7164 and the latest GT1M (GT1M-V3) or the GT1M version one (GT1M-V1) and the GT1M version two (GT1M-V2). Participants walked at 3, 5, and 7 km x h(-1) followed by running at 8, 10, 12, 14, 16, 18, and 20 km x h(-1). The accelerometers were worn on an elastic belt around the waist over the left and right sides of the hip. Testing was performed on different days using a counterbalanced within-subjects design to account for potential differences attributable to accelerometer placement. At each speed, a one-way repeated-measures ANOVA was used to examine differences between activity counts in counts per minute (cpm). Post hoc pairwise comparisons with Bonferroni adjustments were used where appropriate. RESULTS: There were no significant differences between activity counts at any given walking or running speed (P < 0.05). At all running speeds, activity counts from the ActiGraph 7164 and GT1M-V2 displayed the lowest and highest values, respectively. Output from all accelerometers peaked at 14 km x h(-1) (mean range = 8974 +/- 677 to 9412 +/- 982 cpm) and then gradually declined at higher speeds. The mean difference score at peak output between the ActiGraph 7164 and GT1M-V2 was 439 +/- 565 cpm. CONCLUSIONS: There were no statistically significant differences between outputs from all the accelerometers, indicating that researchers can select any of the four ActiGraph accelerometers in doing research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e3181b3af49

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 183

Metadata

Authors
JOHN, D., TYO, B., & BASSETT, D. R.
Venue
Medicine & Science in Sports & Exercise
Published
2010-02
Volume
42
Issue
2
Pages
368-374
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2051045989
Cited by
183
References
4
FWCI
13.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Four ActiGraph Accelerometers during Walking and Running. https://app.cochat.ai/papers/10.1249/mss.0b013e3181b3af49
The paper
JOHN, D., TYO, B., & BASSETT, D. R. (2010). Comparison of Four ActiGraph Accelerometers during Walking and Running. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3181b3af49

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.