Evaluation of Activity Monitors in Controlled and Free-Living Environments
Abstract
UNLABELLED: Numerous studies have established the usefulness of pedometers and accelerometers as objective activity monitors. Under laboratory conditions, some of these devices have been shown to provide accurate and reliable measures of steps. However, limited data exist on the performance of these devices under free-living conditions. PURPOSE: This study aimed 1) to compare the effects of speed and body mass index (BMI) on the step count accuracy of five different accelerometer-based activity monitors and a pedometer during treadmill walking, 2) to compare the performance of these devices in a free-living environment, and 3) to compare the step counts of three generations of a single device (ActiGraph) against a criterion method. METHODS: Fifty-six individuals wore six activity monitors while performing treadmill walking (40, 54, 67, 80, and 94 m·min⁻¹) and during 1 d of free-living activity. The criterion measure of steps during treadmill walking was investigator-determined steps, whereas the criterion measure of steps during the free-living condition was the StepWatch. RESULTS: BMI had no effect on step count accuracy during treadmill walking. The StepWatch, activPAL™, and the AG7164 were the most accurate across all speeds, whereas the remaining devices were only accurate at 67 m·min⁻¹ and faster. In the free-living environment, the AG7164 recorded 99.5% ± 27% (mean ± SD) of StepWatch-determined steps. CONCLUSIONS: We demonstrated that BMI does not affect the step output of commonly used activity monitors during walking. In addition, 67 m·min⁻¹ seems to be the minimum speed required for accurate step counting, at least for most waist-mounted activity monitors. Finally, the StepWatch, AG7164, and activPAL™ were the most accurate devices on the TM, but only the AG7164 yielded comparable step counts to the StepWatch in the free-living environment.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
ActiGraph 7164 step counts are quite similar, on average, to those obtained with the ankle-worn StepWatch, which is often regarded as a suitable criterion for step counting.
“However, the ActiGraph 7164 step counts are quite similar, on average, to those obtained with the ankle-worn StepWatch which is often regarded as a suitable criterion for step counting [58].”
From Step Counting: A Review of Measurement Considerations and Health-Related Applications (2017) · cites this paper as [58]
The citation lists haven’t been fetched yet
References 42 · Cited by 159
- Authors
- FEITO, Y., BASSETT, D. R., & THOMPSON, D. L.
- Affiliations
- Barry University (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-04
- Volume
- 44
- Issue
- 4
- Pages
- 733-741
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1996175347
- Cited by
- 159
- References
- 42
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 10 · 2023: 7 · 2022: 17 · 2021: 14 · 2020: 11 · 2019: 5 · 2018: 14 · 2017: 13 · 2016: 15 · 2015: 8 · 2014: 12 · 2013: 17 · 2012: 5
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- wearable activity trackers, accelerometer, pedometers, step count accuracy, free-living physical activity, treadmill walking, walking speed, body mass index, activPAL, physical activity measurement
- MeSH terms
- Adolescent, Exercise Test, Female, Humans, Male, Motor Activity, Body Mass Index, Walking, Ergometry, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review