The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Assessment of Coronary Intima - Media Thickness by Optical Coherence Tomography Comparison With Intravascular Ultrasound
Open accessAbstract
BACKGROUND: Optical coherence tomography (OCT) is a new imaging method. With a resolution of approximately 10-20 Em, which is approximately 10-fold higher than that of intravascular ultrasound (IVUS). METHODS AND RESULTS: This study compared the coronary intima - media thickness (IMT) and the intimal thickness of 54 coronary arterial segments evaluated by histological examination with the results of OCT and IVUS. There was better agreement in IMT between OCT and histological examination than between IVUS and histological examination (r = 0.95, p < 0.001, mean difference = -0.01+/-0.07 mm for OCT; r = 0.88, p < 0.001, mean difference = -0.03+/-0.10 mm for IVUS). There was good agreement in the intimal thickness between OCT and histological examination (r = 0.98, p < 0.001, mean difference = 0.01+/-0.04 mm). CONCLUSIONS: IMT could be measured more accurately by OCT than IVUS. In addition, the intimal thickness could be evaluated by OCT and correlated well with the histological examination.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404
Cited by
Prati, F., Regar, E., Mintz, G. S., Arbustini, E., Di Mario, C., Jang, I.-K., Akasaka, T., Costa, M., Guagliumi, G., Grube, E., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp433 · Cited by 880
Self-citationAssessment of Culprit Lesion Morphology in Acute Myocardial Infarction
Kubo, T., Imanishi, T., Takarada, S., Kuroi, A., Ueno, S., Yamano, T., Tanimoto, T., Matsuo, Y., Masho, T., Kitabata, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.082 · Cited by 867
Self-citationAssessment of Coronary Arterial Plaque by Optical Coherence Tomography
Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.035 · Cited by 573
Self-citationOptical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Measurement of the thickness of the fibrous cap by optical coherence tomography
Kume, T., Akasaka, T., Kawamoto, T., Okura, H., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.06.030 · Cited by 273
Self-citation
Metadata
- Authors
- Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2005
- Volume
- 69
- Issue
- 8
- Pages
- 903-907
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2076332053
- Cited by
- 206
- References
- 2
- FWCI
- 10.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Coronary Intima - Media Thickness by Optical Coherence Tomography Comparison With Intravascular Ultrasound. https://app.cochat.ai/papers/10.1253/circj.69.903
- The paper
- Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2005). Assessment of Coronary Intima - Media Thickness by Optical Coherence Tomography Comparison With Intravascular Ultrasound. Circulation Journal. https://doi.org/10.1253/circj.69.903
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.