Efficacy of Nasal Bi-Level Positive Airway Pressure in Congestive Heart Failure Patients With Cheyne - Stokes Respiration and Central Sleep Apnea
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Cheyne - Stokes respiration with central sleep apnea (CSR-CSA) contributes to the poor prognosis in patients with congestive heart failure (CHF). Bi-level positive airway pressure (bi-level PAP) may be an effective alternative for treating CSR-CSA and CHF. METHODS AND RESULTS: Fourteen patients with CSR-CSA were divided into 2 groups, a control group that included 7 patients who decided to receive only conventional medications and a group of 7 patients that received bi-level PAP. Left ventricular ejection fraction (LVEF), mitral regurgitation (MR) area, plasma brain natriuretic peptide (BNP) concentration and the New York Heart Association (NYHA) functional class were evaluated initially (baseline) and 3 months later. In the control group, there were no significant changes in cardiac function during the study period. In contrast, in the group that received bi-level PAP, there were significant improvements in LVEF (from 36.3+/-2.9% to 46.0+/-4.0%, p = 0.02), MR area (from 30.4+/-7.6% to 20.0+/-5.1%, p = 0.02), BNP (from 993.6+/-332.0 pg/ml to 474.0+/-257.6 pg/ml, p = 0.02) and NYHA functional class (from 3.1+/-0.1 to 2.1+/-0.1, p = 0.03). CONCLUSION: Treatment with bi-level PAP improved cardiac functions in CHF patients with CSR-CSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aurora, R. N., Chowdhuri, S., Ramar, K., Bista, S. R., Casey, K. R., Lamm, C. I., Kristo, D. A., Mallea, J. M., Rowley, J. A., Zak, R. S., et al. (2012) · Sleep · doi:10.5665/sleep.1580 · Cited by 369
Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
Kasai, T., Narui, K., Dohi, T., Yanagisawa, N., Ishiwata, S., Ohno, M., Yamaguchi, T., & Momomura, S.-I. (2008) · Chest · doi:10.1378/chest.07-1901 · Cited by 238
Self-citationEfficacy of Adaptive Servoventilation in Treatment of Complex and Central Sleep Apnea Syndromes
Allam, J. S., Olson, E. J., Gay, P. C., & Morgenthaler, T. I. (2007) · Chest · doi:10.1378/chest.07-1715 · Cited by 184
Sleep and Breathing in Congestive Heart Failure
Rosen, D., Roux, F. J., & Shah, N. (2014) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2014.06.008 · Cited by 15
Metadata
- Authors
- Kasai, T., Narui, K., Dohi, T., Ishiwata, S., Yoshimura, K., Nishiyama, S.-I., Yamaguchi, T., & Momomura, S.-I.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2005
- Volume
- 69
- Issue
- 8
- Pages
- 913-921
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2084667027
- Cited by
- 76
- References
- 0
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of Nasal Bi-Level Positive Airway Pressure in Congestive Heart Failure Patients With Cheyne - Stokes Respiration and Central Sleep Apnea. https://app.cochat.ai/papers/10.1253/circj.69.913
- The paper
- Kasai, T., Narui, K., Dohi, T., Ishiwata, S., Yoshimura, K., Nishiyama, S.-I., Yamaguchi, T., & Momomura, S.-I. (2005). Efficacy of Nasal Bi-Level Positive Airway Pressure in Congestive Heart Failure Patients With Cheyne - Stokes Respiration and Central Sleep Apnea. Circulation Journal. https://doi.org/10.1253/circj.69.913
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.