The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Present Status of Anticoagulation Treatment in Japanese Patients With Atrial Fibrillation - A Report From the J-RHYTHM Registry -
Open accessAbstract
BACKGROUND: Underuse and an inadequate range for the international normalized ratio (INR) for warfarin use are still problems in the management of the patients with atrial fibrillation (AF) in Japan. METHODS AND RESULTS: From January to July 2009, a total of 7,937 AF patients [5,468 men (68.6 ± 10.0 years) and 2,469 women (72.2 ± 9.0 years)] were registered from 158 institutions for the J-RHYTHM Registry. Overall, 34.2% of the patients were over the age of 75. The associated cardiovascular diagnoses were hypertension in 59.1%, coronary artery disease in 10.1%, cardiomyopathy in 8.3%, valvular heart disease in 13.7% and artificial cardiac valves in 3.1% of the patients. The type of AF was paroxysmal in 37.1%, persistent in 14.4%, and permanent in 48.5%. Overall, 87.3% of patients were taking warfarin (2.9 ± 1.2mg/day), of whom 66.0% had an INR between 1.6 and 2.6, and 35.4% were in the INR range from 2.0 to 3.0 at the time of registration. Aspirin was prescribed in 22.3% of cases. The CHADS2 score was 0 in 15.7% of patients, 1 in 34.0%, and ≥ 2 in 50.3%. CONCLUSIONS: At present, warfarin is used extensively in patients with AF whose stroke risk is relatively low (ie, in Japan) and half of them had CHADS2 scores of 0 to 1 (UMIN Clinical Trials Registry UMIN000001569).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Self-citationRhythm control versus rate control for atrial fibrillation and heart failure
Roy, D., Talajic, M., Nattel, S., Wyse, D. G., Dorian, P., Lee, K. L., Bourassa, M. G., Arnold, J. M. O., Buxton, A. E., Camm, A. J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708789 · Cited by 1,585
Cited by
Global epidemiology of atrial fibrillation
Rahman, F., Kwan, G. F., & Benjamin, E. J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.118 · Cited by 731
Rivaroxaban vs. Warfarin in Japanese Patients With Atrial Fibrillation: – The J-ROCKET AF Study –
Hori, M., Matsumoto, M., Tanahashi, N., Momomura, S.-I., Uchiyama, S., Goto, S., Izumi, T., Koretsune, Y., Kajikawa, M., Kato, M., et al. (2012) · Circulation Journal · doi:10.1253/circj.cj-12-0454 · Cited by 641
Metadata
- Authors
- Atarashi, H., Inoue, H., Okumura, K., Yamashita, T., Kumagai, N., Origasa, H., & The J-RHYTHM Registry Investigators
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2011
- Volume
- 75
- Issue
- 6
- Pages
- 1328-1333
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W2313055962
- Cited by
- 199
- References
- 3
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Present Status of Anticoagulation Treatment in Japanese Patients With Atrial Fibrillation - A Report From the J-RHYTHM Registry -. https://app.cochat.ai/papers/10.1253/circj.cj-10-1119
- The paper
- Atarashi, H., Inoue, H., Okumura, K., Yamashita, T., Kumagai, N., Origasa, H., & The J-RHYTHM Registry Investigators. (2011). Present Status of Anticoagulation Treatment in Japanese Patients With Atrial Fibrillation - A Report From the J-RHYTHM Registry -. Circulation Journal. https://doi.org/10.1253/circj.cj-10-1119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.