The DOI matches its Crossref record.
Investigation of a LOCAL Calibration Procedure for near Infrared Instruments
Abstract
A new procedure (LOCAL) for local calibrations is presented. LOCAL selects spectra from a library of samples and computes a PLS calibration equation for each constituent of the sample. This study evaluated the performances of LOCAL on the prediction of ground corn grain and haylage using several different combinations of data transformations, wavelength segment reduction, number of PLS factors and samples used in calibration. LOCAL resulted in lower SEP values for all the constituents of corn and dry matter of haylage with improvements ranging between 6 to 13%. Global calibrations had only a small advantage over LOCAL (1–2%) in the prediction of acid detergent fibre and crude protein in haylage. The two most important variables controlling the accuracy of predictions were number of samples in the calibration and number of PLS factors in the solution. Best results were obtained using 150 to 225 samples and more than 20 PLS factors per calibration equation. The speed of the LOCAL procedure is 0.5–2 s per sample on a 90 MHz computer. With this speed and accuracy, LOCAL is now available for real-time routine operation on a Windows platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Soriano-Disla, J. M., Janik, L. J., Viscarra Rossel, R. A., Macdonald, L. M., & McLaughlin, M. J. (2014) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2013.811081 · Cited by 848
Nocita, M., Stevens, A., Toth, G., Panagos, P., van Wesemael, B., & Montanarella, L. (2014) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2013.10.022 · Cited by 325
Bi, Y., Yuan, K., Xiao, W., Wu, J., Shi, C., Xia, J., Chu, G., Zhang, G., & Zhou, G. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.01.010 · Cited by 275
Assessment and monitoring of soil quality using near-infrared reflectance spectroscopy (NIRS)
Cécillon, L., Barthès, B. G., Gomez, C., Ertlen, D., Genot, V., Hedde, M., Stevens, A., & Brun, J. J. (2009) · European Journal of Soil Science · doi:10.1111/j.1365-2389.2009.01178.x · Cited by 247
Challagulla, V., Walsh, K. B., & Subedi, P. (2014) · BioEnergy Research · doi:10.1007/s12155-013-9373-9 · Cited by 16
Metadata
- Authors
- Shenk, J. S., Westerhaus, M. O., & Berzaghi, P.
- Venue
- Journal of Near Infrared Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1997-10
- Volume
- 5
- Issue
- 4
- Pages
- 223-232
- ISSN
- 0967-0335 (ISSN-L)
- 1751-6552
- OpenAlex
- W2062569668
- Cited by
- 194
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation of a LOCAL Calibration Procedure for near Infrared Instruments. https://app.cochat.ai/papers/10.1255/jnirs.115
- The paper
- Shenk, J. S., Westerhaus, M. O., & Berzaghi, P. (1997). Investigation of a LOCAL Calibration Procedure for near Infrared Instruments. Journal of Near Infrared Spectroscopy. https://doi.org/10.1255/jnirs.115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.