The DOI matches its Crossref record.
Near Infrared Spectroscopy and Chemometrics Studies of Temperature-Dependent Spectral Variations of Water: Relationship between Spectral Changes and Hydrogen Bonds
Abstract
The present study aims to provide new insights into the temperature-dependent spectral variations in the near infrared (NIR) region of the spectrum of water by comparing chemometrics with spectroscopic analysis. Fourier transform (FT)-NIR spectra of water in the 9000–5500 cm−1 region have been measured over a temperature range of 5–85°C. The observed spectral changes have been analysed by both chemometrics, such as multilinear regression (MLR), principal component regression (PCR) and partial least squares (PLS) regression, and spectroscopic data analyses, such as second derivative, difference spectra and curve fitting. The second derivative of the NIR spectra of water suggests that an intense feature around 6900 cm−1, due to the combination of antisymmetric and symmetric stretching modes of water, consists of at least five component spectra. Each component spectrum may be ascribed to the water species with no, one, two, three and four hydrogen bonds. Curve fitting has been performed for the 6900 cm−1 band and it has been found that the species with no hydrogen bonds increase largely with temperature, while those with more than two hydrogen bonds decrease. The temperature of water has been predicted by use of MLR, PCR and PLS regression. PCR and PLS regression loadings plots for Factor 1 of the models for the prediction of the temperature of water are almost identical with the difference spectrum of water between 5 and 85°C; both the loadings plots and the difference spectrum reflect strongly the changes in the hydrogen bonds of water. Loadings plots of Factor 1 of the PCR and PLS regression models are very similar to each other. It is very likely that since the temperature-dependent spectral variations of water in the NIR region are very regular, and the spectra have only very small noise and baseline changes, PCR and PLS regression select nearly identical factors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252
Golic, M., Walsh, K., & Lawson, P. (2003) · Applied Spectroscopy · doi:10.1366/000370203321535033 · Cited by 289
Inagaki, T., Yonenobu, H., & Tsuchikawa, S. (2008) · Applied Spectroscopy · doi:10.1366/000370208785284312 · Cited by 61
Metadata
- Authors
- Maeda, H., Ozaki, Y., Tanaka, M., Hayashi, N., & Kojima, T.
- Venue
- Journal of Near Infrared Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1995-10
- Volume
- 3
- Issue
- 4
- Pages
- 191-201
- ISSN
- 0967-0335 (ISSN-L)
- 1751-6552
- OpenAlex
- W1965336656
- Cited by
- 251
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near Infrared Spectroscopy and Chemometrics Studies of Temperature-Dependent Spectral Variations of Water: Relationship between Spectral Changes and Hydrogen Bonds. https://app.cochat.ai/papers/10.1255/jnirs.69
- The paper
- Maeda, H., Ozaki, Y., Tanaka, M., Hayashi, N., & Kojima, T. (1995). Near Infrared Spectroscopy and Chemometrics Studies of Temperature-Dependent Spectral Variations of Water: Relationship between Spectral Changes and Hydrogen Bonds. Journal of Near Infrared Spectroscopy. https://doi.org/10.1255/jnirs.69
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.