Near Infrared Brain and Muscle Oximetry: From the Discovery to Current Applications
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In the early 1960s, Norris introduced near infrared (NIR) spectroscopy (700–2500 nm) as an analytical technique for agricultural products. In 1977, Jöbsis founded in vivo medical NIR spectroscopy, reporting that the relatively high degree of transparency of brain tissue in the NIR spectral window (700–1000 nm) enables safe real-time non-invasive detection of regional haemoglobin oxygenation using trans-illumination spectroscopy. In order to place current medical NIR spectroscopy in its proper perspective, this review provides a snapshot of the roots of the discovery and the early years of medical NIR spectroscopy research and development. Starting in 1992, the opportunity of measuring quantitatively, by different NIR spectroscopy techniques, regional oxy-haemoglobin saturation by NIR oximetry, it is possible to monitor brain/muscle reserve capacity following tissue oxygen extraction in different pathophysiological conditions. This review reports the status of the current commercial oximeters (including wireless instrumentation) and their main clinical and physiological applications. In the last decade, NIR spectroscopy brain oximetry has obtained significant clinical relevance as suggested by the more than 10,000 instruments sold and the high number of related scientific publications. The most relevant clinical application is represented by the evaluation of cerebral oxy-haemoglobin saturation during adult cardiac surgery and cardiopulmonary bypass. Many commercial oximeters are presently available. However, their relatively poor precision and the lack of standardisation amongst the different instruments suggest that further technological advances are required before NIR spectroscopy oximetry can be adopted more widely under the “guidelines” of regulatory authorities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationQuantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Self-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationMuscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“…adults and newborns at risk of brain hypoxia/ischemia, permitting clinicians to detect and correct a variety of life threatening complications and improve clinical outcomes (for a review: Drayna et al., 2011; Ferrari and Quaresima, 2012; Greisen et al., 2011; Smith, 2011; Wolf et al., 2012).”
Self-citationDiffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“(topography), are commercially available and largely utilized in different areas in the field of neuroscience.(25,215) Unfortunately,”
BackgroundSelf-citationZheng, F., Sheinberg, R., Yee, M.-S., Ono, M., Zheng, Y., & Hogue, C. W. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318277a255 · Cited by 299
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“The NIRS signals are the result of the weighted average of the oxygen saturations of the heme group of hemoglobins (Hbs) in the vascular bed (small arteries, arterioles, capillaries, venules, small veins) and the heme group of myoglobin (Mb) in the muscle fibers [1, 2].”
BackgroundSelf-citationWang, X., Tian, F., Soni, S. S., Gonzalez-Lima, F., & Liu, H. (2016) · Scientific Reports · doi:10.1038/srep30540 · Cited by 219
“While the actual implementation of this approach started more than 20 years ago 30,31 , it had uncertainty on the accuracy of the methodology 29,32,33 .”
Yu, Y., Zhang, K., Zhang, L., Zong, H., Meng, L., & Han, R. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010947.pub2 · Cited by 179
Koga, S., Barstow, T. J., Okushima, D., Rossiter, H. B., Kondo, N., Ohmae, E., & Poole, D. C. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01003.2014 · Cited by 60
SUN, Y., FERGUSON, B. S., ROGATZKI, M. J., MCDONALD, J. R., & GLADDEN, L. B. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001001 · Cited by 16
Metadata
- Authors
- Ferrari, M., & Quaresima, V.
- Venue
- Journal of Near Infrared Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2012-01-01
- Volume
- 20
- Issue
- 1
- Pages
- 1-14
- ISSN
- 0967-0335 (ISSN-L)
- 1751-6552
- OpenAlex
- W2095211141
- Cited by
- 116
- References
- 7
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.