Development of a method for the measurement of dehydroepiandrosterone sulphate by liquid chromatography-tandem mass spectrometry
Open accessThe DOI matches its Crossref record.
Abstract
Background: Dehydroepiandrosterone sulphate (DHEAS) is a steroid that is increasingly being recognized as a potential drug of abuse in many countries. This is due to its reputation as a hormone that may be able to retard the ageing process. The measurement of DHEAS is useful in the diagnosis of medical conditions such as congenital adrenal hyperplasia and polycystic ovary syndrome. Thus, a liquid chromatography-tandem mass spectrometry method has been developed to determine DHEAS concentrations in human serum. Method: The chromatography was performed using a Waters TM 2795 Alliance HT LC system coupled to a Mercury Fusion-RP column fitted with a SecurityGuard TM column. Results: DHEAS and the internal standard, deuterated DHEAS, both had a retention time of 1.5 min. The transition determined by the Micromass Quattro TM tandem mass spectrometer for DHEAS was m/z 367.3>96.7 and for the internal standard m/z 369.3>96.6. The method was linear up to 20 µmol/L; the lower limit of detection and the lower limit of quantitation were both 1 µmol/L. The intra- and interassay imprecision were <11% over a concentration range of 1-18 µmol/L for the in-house quality control and <12% for the intra- and interassay imprecision for the Bio-Rad Lyphocheck QC. Conclusion: The measurement of DHEAS by liquid chromatography-tandem mass spectrometry is robust and has a simple sample preparation procedure with a rapid cycle time of only 4 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lindheim, L., Bashir, M., Münzker, J., Trummer, C., Zachhuber, V., Leber, B., Horvath, A., Pieber, T. R., Gorkiewicz, G., Stadlbauer, V., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0168390 · Cited by 416
Androgen therapy in women: a reappraisal: an Endocrine Society Clinical Practice Guideline
Wierman, M. E., Arlt, W., Basson, R., Davis, S. R., Miller, K. K., Murad, M. H., Rosner, W., & Santoro, N. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2260 · Cited by 363
O'Reilly, M. W., Taylor, A. E., Crabtree, N. J., Hughes, B. A., Capper, F., Crowley, R. K., Stewart, P. M., Tomlinson, J. W., & Arlt, W. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-3399 · Cited by 283
11-Oxygenated C19 steroids are the predominant androgens in polycystic ovary syndrome
O’Reilly, M. W., Kempegowda, P., Jenkinson, C., Taylor, A. E., Quanson, J. L., Storbeck, K.-H., & Arlt, W. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-3285 · Cited by 267
O’Reilly, M. W., Kempegowda, P., Walsh, M., Taylor, A. E., Manolopoulos, K. N., Allwood, J. W., Semple, R. K., Hebenstreit, D., Dunn, W. B., Tomlinson, J. W., et al. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-00947 · Cited by 215
“Serum DHEAS was extracted from 20μL of serum with 100 μL acetonitrile, before evaporation under constant n itrogen flow (28).”
Metadata
- Authors
- Chadwick, C. A., Owen, L. J., & Keevil, B. G.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2005-11-01
- Volume
- 42
- Issue
- 6
- Pages
- 468-474
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2032150461
- Cited by
- 36
- References
- 0
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a method for the measurement of dehydroepiandrosterone sulphate by liquid chromatography-tandem mass spectrometry. https://app.cochat.ai/papers/10.1258/000456305774538175
- The paper
- Chadwick, C. A., Owen, L. J., & Keevil, B. G. (2005). Development of a method for the measurement of dehydroepiandrosterone sulphate by liquid chromatography-tandem mass spectrometry. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/000456305774538175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.