Measurement of serum testosterone in women; what should we do?
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
All immunoassays for female serum testosterone give falsely high results in some samples. The effect is variable and cannot be predicted for any given sample. Inaccurate calibration or interference by cross-reacting substances is almost certainly the cause of the problem, but for many immunoassays, the exact nature of the interferent is not known. Some of the interference can be removed by employing an extraction step prior to immunoassay. The advent of fast simple and sensitive liquid chromatography tandem mass spectrometry methods offers an exciting alternative to immunoassay for serum testosterone measurement. It is recommended that all high serum testosterone concentrations in women are checked, before reporting, by a method which is accurate (i.e. minimal bias to isotope dilution gas chromatography mass spectrometry [ID-GCMS] method) and is not subject to interference. Action should also be taken by assay users, manufacturers, regulators and professional bodies to ensure accurate standardization and comparability of assays.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Daily physiologic cortisol production in healthy individuals is about 5-10 mg per square meter of body surface area (107), corresponding to a replacement dose of approximately 15-20 mg/day.”
From Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline (2016) · cites this paper as [107]
In the citing paper
“Cortisol secretion exhibits a distinct circadian rhythm; low at the time of sleep onset, rising early morning, peaking just after the time of waking, then falling during the day (28,107).”
From Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline (2016) · cites this paper as [107]
Citations
Cites
Franks, S. (1995) · New England Journal of Medicine · doi:10.1056/nejm199509283331307 · Cited by 2,463
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580
Selby, C. (1999) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329903600603 · Cited by 316
Immunoassays for Testosterone in Women: Better than a Guess?
Herold, D. A., & Fitzgerald, R. L. (2003) · Clinical Chemistry · doi:10.1373/49.8.1250 · Cited by 203
Performance Characteristics of a Novel Tandem Mass Spectrometry Assay For Serum Testosterone
Kushnir, M. M., Rockwood, A. L., Roberts, W. L., Pattison, E. G., Bunker, A. M., Fitzgerald, R. L., & Meikle, A. W. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.052167 · Cited by 170
Non-Sex Hormone-Binding Globulin-Bound Testosterone as a Marker for Hyperandrogenism*
CUMMING, D. C., & WALI, S. R. (1985) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-61-5-873 · Cited by 158
O'Driscoll, J. B., Mamtora, H., Higginson, J., Pollock, A., Kane, J., & Anderson, D. C. (1994) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1994.tb02535.x · Cited by 152
Self-citationFox, R., Corrigan, E., Thomas, P. A., & Hull, M. G. R. (1991) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1991.tb00282.x · Cited by 142
Siekmann, L. (1979) · Journal of Steroid Biochemistry · doi:10.1016/0022-4731(79)90285-1 · Cited by 134
Measurement of steroid sex hormones in serum: a comparison of radioimmunoassay and mass spectrometry
Dorgan, J. F., Fears, T. R., McMahon, R. P., Friedman, L. A., Patterson, B. H., & Greenhut, S. F. (2002) · Steroids · doi:10.1016/s0039-128x(01)00147-7 · Cited by 123
Cited by
Hormonal Replacement in Hypopituitarism in Adults: An Endocrine Society Clinical Practice Guideline
Fleseriu, M., Hashim, I. A., Karavitaki, N., Melmed, S., Murad, M. H., Salvatori, R., & Samuels, M. H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2118 · Cited by 945
Traceability in Laboratory Medicine
Vesper, H. W., & Thienpont, L. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.107052 · Cited by 168
Vesper, H. W., Bhasin, S., Wang, C., Tai, S. S., Dodge, L. A., Singh, R. J., Nelson, J., Ohorodnik, S., Clarke, N. J., Salameh, W. A., et al. (2009) · Steroids · doi:10.1016/j.steroids.2009.01.004 · Cited by 152
Standardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Al-Kindi, M., Essry, F. S. A., Al-Essry, F. S., & Mula-Abed, W.-A. S. (2012) · Oman Medical Journal · doi:10.5001/omj.2012.112 · Cited by 110
Metadata
- Authors
- Kane, J., Middle, J., & Cawood, M.
- Affiliations
- Salford Royal Hospital (GB)
- Wolfson EQA Laboratory, PO Box 3909, Birmingham B15 2UE
- University of Leeds (GB)
- ORCID
- Kane, John
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2007-01-01
- Volume
- 44
- Issue
- 1
- Pages
- 5-15
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2019836287
- Cited by
- 49
- References
- 26
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 1 · 2022: 1 · 2019: 4 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 7 · 2012: 5
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hormonal and reproductive studies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- serum testosterone, women, immunoassay interference, assay standardization, liquid chromatography-tandem mass spectrometry, assay comparability
- MeSH terms
- Chromatography, Liquid, Female, Humans, Immunoassay, Sensitivity and Specificity, Mass Spectrometry, Testosterone, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of serum testosterone in women; what should we do? https://app.cochat.ai/papers/10.1258/000456307779595896
- The paper
- Kane, J., Middle, J., & Cawood, M. (2007). Measurement of serum testosterone in women; what should we do? Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/000456307779595896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.