EDTA analysis on the Roche MODULAR® analyser
The DOI matches its Crossref record.
Abstract
Background: Patient specimens can be subject to subtle interference from cross contamination by liquid-based, potassium-containing EDTA anticoagulant, leading to misinterpretation of results. A rapid method for EDTA analysis to detect such contamination is described. Method: An in-house EDTA assay on the Roche MODULAR® analyser was assessed for accuracy and precision by comparison with an adjusted calcium difference measurement (atomic absorption and o-cresolphthalein complexone colorimetry). Results: EDTA method versus adjusted calcium difference showed: slope = 1.038 (95% confidence interval [CI] 0.949-1.131); intercept = 0.073 (95% CI 0.018-0.132) mmol/L; r = 0.914; n = 94. However, inter-assay precision of the calcium difference method was estimated to be poorer (coefficient of variation 24.8% versus 3.4% for the automated colorimetric method at an EDTA concentration of 0.25 mmol/L). Unequivocal contamination was observed at an EDTA concentration of -0.2 mmol/L. The automated method showed positive interference from haemolysis and negative interference from oxalate. The method was unaffected by lipaemia (triglycerides <20 mmol/L), icterus (bilirubin <500 μmol/L), glucose (<100 mmol/L), iron (<100 μmol/L), and citrate, phosphate or fluoride (all <2.5 mmol/L). Conclusion: The automated colorimetric assay described is an accurate, precise and rapid (3 min) means of detecting EDTA contamination of unhaemolysed biochemistry specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Cornes, M. P., Ford, C., & Gama, R. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.007241 · Cited by 69
Sharratt, C. L., Gilbert, C. J., Cornes, M. C., Ford, C., & Gama, R. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01981.x · Cited by 66
Effect of order of draw of blood samples during phlebotomy on routine biochemistry results: Table 1
Sulaiman, R. A., Cornes, M. P., Whitehead, S. J., Othonos, N., Ford, C., & Gama, R. (2011) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2011-200206 · Cited by 40
Case report of unexplained hypocalcaemia in a slightly haemolysed sample
Cornes, M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.046 · Cited by 7
Metadata
- Authors
- Davidson, D. F.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2007-05-01
- Volume
- 44
- Issue
- 3
- Pages
- 294-296
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2096312835
- Cited by
- 24
- References
- 0
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EDTA analysis on the Roche MODULAR® analyser. https://app.cochat.ai/papers/10.1258/000456307780480846
- The paper
- Davidson, D. F. (2007). EDTA analysis on the Roche MODULAR® analyser. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/000456307780480846
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.