CoChat

Celon® radiofrequency thermo-ablative palatoplasty for snoring - a pilot study

Tatla, T., Sandhu, G., Croft, C. B., Kotecha, B. · 2003 · The Journal of Laryngology & Otology
Cited by 26

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A prospective non-randomized study was designed to investigate the effects of Celon® radio-frequency thermo-ablation (RFTA) of the soft palate in patients with snoring/mild obstructive sleep apnoea. Ten patients, fulfilling various inclusion/exclusion criteria, underwent single operator sub-mucosal RFTA palatoplasty as an office procedure. Two separate procedures six weeks apart involved each patient receiving six distinct sub-mucosal lesions on each visit. Questionnaires including visual analogue scales (VAS) were used to evaluate post-operative pain and subjective snoring (scored by patient/partner). Polysomnography (PSG) was performed pre-operation and three months following the second procedure. Using non-parametric statistical analysis, a significant reduction in VAS snoring was noted from initial levels to those scored at six and 16 weeks in nine of 10 patients (p = 0.013 and p = 0.007 respectively). (Five of these nine showed a greater than 50 per cent reduction in score). Objectively, six of 10 patients had a reduction in the apnoea-hypopnea Index between the two PSGs, (four of these six showed a greater than 50 per cent reduction) however, this was not statistically significant. Subjective assessment of the PSG snoring signal by the senior author showed eight of 10 patients had either a reduced or much reduced signal at four months. VAS pain confirmed both procedures are well tolerated with minimal analgesia requirements. Minor complaints of transient mild palatal swelling, dry throat, catarrh and referred otalgia were noted and one patient developed mucosal ulceration following both procedures that healed within three weeks. Swallowing and speech were unaffected. These results confirm similar findings using the Somnus® Unit, although the Celon® device provides additional advantages ncluding inherent safety in a bipolar electrode tip, auto-stop energy application and reduced procedure time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1258/002221503770716241

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 26

Metadata

Authors
Tatla, T., Sandhu, G., Croft, C. B., & Kotecha, B.
Venue
The Journal of Laryngology & Otology
Published
2003-10
Volume
117
Issue
10
Pages
801-806
ISSN
  • 0022-2151 (ISSN-L)
  • 1748-5460
OpenAlex
W2018855879
Cited by
26
References
1
FWCI
0.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Celon® radiofrequency thermo-ablative palatoplasty for snoring - a pilot study. https://app.cochat.ai/papers/10.1258/002221503770716241
The paper
Tatla, T., Sandhu, G., Croft, C. B., & Kotecha, B. (2003). Celon® radiofrequency thermo-ablative palatoplasty for snoring - a pilot study. The Journal of Laryngology & Otology. https://doi.org/10.1258/002221503770716241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.