The scope for improving the design of laboratory animal experiments
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The factors which need to be taken into account in designing a 'good' experiment are reviewed. Such an experiment should be unbiased, have high precision, a wide range of applicability, it should be simple, and there should be a means of quantifying uncertainty (Cox 1958). The relative precision due to the use of randomized block designs was found to range from 96% to 543% in 5 experiments involving 30 variables. However, a survey of 78 papers published in two toxicology journals showed that such designs were hardly used. Similarly, designs in which more than one factor was varied simultaneously ('factorial designs') were only used in 9% of studies, though interactions between variables such as dose and strain of animal may be common, so that single factor experiments could be misleading. The consequences of increased within-group variability due to infection and genetic segregation were quantified using data published by Gärtner (1990). Both substantially reduced precision, but toxicologists continue to use non-isogenic laboratory animals, leading to experiments with a lower level of precision than is necessary. It is concluded that there is scope for improving the design of animal experiments, which could lead to a reduction in animal use. People using animals should be required to take formal training courses which include sessions on experimental design in order to minimize animal use and to increase experimental efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gärtner, K. (1990) · Laboratory Animals · doi:10.1258/002367790780890347 · Cited by 241 · cited 3×
“1 (Gartner, 1990), which shows variation (range or coefficient of variation) in kidney”
BackgroundMethodInfluentialPohjanvirta, R., Juvonen, R., Kärenlampi, S., Raunio, H., & Tuomisto, J. (1988) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(88)90235-9 · Cited by 85
Cited by
Hooijmans, C. R., Leenaars, M., & Ritskes-Hoitinga, M. (2010) · Alternatives to Laboratory Animals · doi:10.1177/026119291003800208 · Cited by 311
Hooijmans, C. R., Tillema, A., Leenaars, M., & Ritskes-Hoitinga, M. (2010) · Laboratory Animals · doi:10.1258/la.2010.009117 · Cited by 297
Tractenberg, S. G., Levandowski, M. L., de Azeredo, L. A., Orso, R., Roithmann, L. G., Hoffmann, E. S., Brenhouse, H., & Grassi-Oliveira, R. (2016) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2016.06.021 · Cited by 267
Evaluation and applications of radiotelemetry in small laboratory animals
Kramer, K., & Kinter, L. B. (2003) · Physiological Genomics · doi:10.1152/physiolgenomics.00164.2002 · Cited by 221
“Use of blocked study designs filters out the inter-animal variation and reduces the numbers of animals needed to obtain the same level of statistical power for evaluating dose/ treatment responses (27, 90).”
BackgroundOn determining sample size in experiments involving laboratory animals
Festing, M. F. (2018) · Laboratory Animals · doi:10.1177/0023677217738268 · Cited by 213
Self-citation
Metadata
- Authors
- Festing, M. F. W.
- Venue
- Laboratory Animals
- Publisher
- SAGE Publications
- Published
- 1992-10-01
- Volume
- 26
- Issue
- 4
- Pages
- 256-268
- ISSN
- 0023-6772 (ISSN-L)
- 1758-1117
- OpenAlex
- W2135374893
- Cited by
- 71
- References
- 2
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.