Errors in dual-energy X-ray absorptiometry of the lumbar spine owing to fat distribution and soft tissue thickness during weight change
The DOI matches its Crossref record.
Abstract
It has previously been shown that the non-uniform distribution of fat leads to errors in the determination of spine bone mineral. If the fat error changes during alterations of weight, conclusions about bone mineral measurements might be compromised. To test this possibility, the distribution of adipose tissue was determined from X-ray CT scans taken for diagnostic purposes from patients whose weight had increased or decreased due to disease or treatment. For AP scanning the change in mean fat thickness over the vertebrae was similar to that in the background area, so that there was little change in fat error and therefore no misinterpretation of bone mineral measurements. Results were more variable for lateral scanning, sufficiently so as to question its validity in this context. The dependence of bone mineral measurements on the soft tissue thickness was investigated with three different makes of dual-energy X-ray absorptiometer and four spine models. A complex dependence was found, which varied with the bone mineral density, the thickness, the machine and the model. However, the magnitude of the dependence was not sufficient to falsify the conclusions about changes in bone mineral in two clinical studies in which patients had changed weight.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DXA scanning in clinical practice
El Maghraoui, A., & Roux, C. (2008) · QJM · doi:10.1093/qjmed/hcn022 · Cited by 323
Nguyen, T. V., Sambrook, P. N., & Eisman, J. A. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.9.1458 · Cited by 298
Technical principles of dual energy X-ray absorptiometry
Blake, G. M., & Fogelman, I. (1997) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(97)80025-6 · Cited by 295
Johannsson, G. (1996) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.81.8.2865 · Cited by 258
Bone and gastric bypass surgery: effects of dietary calcium and vitamin D
Goode, L. R., Brolin, R. E., Chowdhury, H. A., & Shapses, S. A. (2004) · Obesity Research · doi:10.1038/oby.2004.7 · Cited by 233
Metadata
- Authors
- Tothill, P., & Avenell, A.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-01-01
- Volume
- 67
- Issue
- 793
- Pages
- 71-75
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1994054105
- Cited by
- 81
- References
- 0
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Errors in dual-energy X-ray absorptiometry of the lumbar spine owing to fat distribution and soft tissue thickness during weight change. https://app.cochat.ai/papers/10.1259/0007-1285-67-793-71
- The paper
- Tothill, P., & Avenell, A. (1994). Errors in dual-energy X-ray absorptiometry of the lumbar spine owing to fat distribution and soft tissue thickness during weight change. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-67-793-71
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.