The future of image-guided radiotherapy will be MR guided
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Advances in image-guided radiotherapy (RT) have allowed for dose escalation and more precise radiation treatment delivery. Each decade brings new imaging technologies to help improve RT patient setup. Currently, the most frequently used method of three-dimensional pre-treatment image verification is performed with cone beam CT. However, more recent developments have provided RT with the ability to have on-board MRI coupled to the teleradiotherapy unit. This latest tool for treating cancer is known as MR-guided RT. Several varieties of these units have been designed and installed in centres across the globe. Their prevalence, history, advantages and disadvantages are discussed in this review article. In preparation for the next generation of image-guided RT, this review also covers where MR-guided RT might be heading in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989 · cited 1×
“Thus lower apparent diffusion coefficient can be used for tumour detection as well as treatment response and prediction.(54,55) Similarly, diffusion tensor imaging has been shown to improve delineation of difficult-to-treat high-grade gliomas than using only T1 weighted images.”
BackgroundChang, J. Y., Senan, S., Paul, M. A., Mehran, R. J., Louie, A. V., Balter, P., Groen, H. J. M., McRae, S. E., Widder, J., Feng, L., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(15)70168-3 · Cited by 1,462
The ViewRay System: Magnetic Resonance–Guided and Controlled Radiotherapy
Mutic, S., & Dempsey, J. F. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.008 · Cited by 915 · cited 16×
“This latest tool for treating cancer is known as MR-guided RT.”
BackgroundMethodInfluentialSturdza, A., Pötter, R., Fokdal, L. U., Haie-Meder, C., Tan, L. T., Mazeron, R., Petric, P., Šegedin, B., Jurgenliemk-Schulz, I. M., Nomden, C., et al. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.03.011 · Cited by 715
Simultaneous multislice (SMS) imaging techniques
Barth, M., Breuer, F., Koopmans, P. J., Norris, D. G., & Poser, B. A. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25897 · Cited by 534 · cited 1×
“It is to be noted that recent developments such as multiplexed sensitivity encoding and simultaneous multislice potentially provide sufficient spatial resolution to be used for real-time image guidance.(61,62)”
BackgroundLagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511 · cited 4×
“5-T magnetic field was that the proton beam dose distribution was not affected much.(17,78) They calculated no effect of the magnetic field on the proton beam at tissue–air interfaces and minimal disruption of the dose distribution since the secondary electrons produced by proton beams have low energy.”
BackgroundMethodInfluentialFluorine (19F) MRS and MRI in biomedicine
Ruiz‐Cabello, J., Barnett, B. P., Bottomley, P. A., & Bulte, J. W. M. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1570 · Cited by 489 · cited 4×
“This produces the desired chemical shift to be effective as a contrast agent.(64) (19)F nuclear MR can be used for functional lung imaging, cell tracking using PFC emulsions and in vivo monitoring of fluorinated drugs and their metabolites such as chemotherapy agents.”
BackgroundInfluentialThe Magnetic Resonance Imaging–Linac System
Lagendijk, J. J. W., Raaymakers, B. W., & van Vulpen, M. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.009 · Cited by 464 · cited 4×
“5-T Achieva® Philips MRI and an Elekta 6-MV accelerator in a ring configured in the mid-transversal plane about the MR.(14,26,27) The team is still working to create a realtime Monte Carlo-based TPS that will allow for online, duringtreatment adaptive planning for their unit.”
BackgroundInfluentialInnovations in image-guided radiotherapy
Verellen, D., Ridder, M. D., Linthout, N., Tournel, K., Soete, G., & Storme, G. (2007) · Nature Reviews Cancer · doi:10.1038/nrc2288 · Cited by 384
Raaijmakers, A. J. E., Raaymakers, B. W., & Lagendijk, J. J. W. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/7/002 · Cited by 380 · cited 1×
“And as early as 2004, Raaijmakers et al(13) published the findings of their feasibility study to integrate a 6-MV linear accelerator (linac) with an MRI unit.(12,13) In a collaboration between Elekta Oncology Systems and Philips Medical Systems, the team designed a 6-MV linear accelerator that rotates about the gantry…”
Background
Cited by
Peerlings, J., Woodruff, H. C., Winfield, J. M., Ibrahim, A., Van Beers, B. E., Heerschap, A., Jackson, A., Wildberger, J. E., Mottaghy, F. M., DeSouza, N. M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-41344-5 · Cited by 266
Metadata
- Authors
- Pollard, J. M., Wen, Z., Sadagopan, R., Wang, J., & Ibbott, G. S.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-05
- Volume
- 90
- Issue
- 1073
- Pages
- 20160667
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2591910347
- Cited by
- 201
- References
- 40
- FWCI
- 17.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.