Multiple sclerosis update: use of MRI for early diagnosis, disease monitoring and assessment of treatment related complications
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
MRI has long been established as the most sensitive in vivo technique for detecting multiple sclerosis (MS) lesions. The 2010 revisions of the McDonald Criteria have simplified imaging criteria, such that a diagnosis of MS can be made on a single contrast-enhanced MRI scan in the appropriate clinical context. New disease-modifying therapies have proven effective in reducing relapse rate and severity. Several of these therapies, most particularly natalizumab, but also dimethyl fumarate and fingolimod, have been associated with progressive multifocal leukoencephalopathy (PML). PML-immune reconstitution inflammatory syndrome (IRIS) has been recognized in patients following cessation of natalizumab owing to PML, and discontinuation for other reasons can lead to the phenomenon of rebound MS. These complications often provide a diagnostic dilemma and have implications for imaging surveillance of patients. We demonstrate how the updated McDonald Criteria aid the diagnosis of MS and describe the imaging characteristics of conditions such as PML and PML-IRIS in the context of MS. Potential imaging surveillance protocols are considered for the diagnosis and assessment of complications. We will explain how changes in MS treatment are leading to new imaging demands in order to monitor patients for disease progression and treatment-related complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidental MRI anomalies suggestive of multiple sclerosis: The radiologically isolated syndrome
Okuda, D. T., Mowry, E. M., Beheshtian, A., Waubant, E., Baranzini, S. E., Goodin, D. S., Hauser, S. L., & Pelletier, D. (2009) · Neurology · doi:10.1212/01.wnl.0000335764.14513.1a · Cited by 642
on behalf of the MAGNIMS study group, Rovira, À., Wattjes, M. P., Tintoré, M., Tur, C., Yousry, T. A., Sormani, M. P., De Stefano, N., Filippi, M., Auger, C., et al. (2015) · Nature Reviews Neurology · doi:10.1038/nrneurol.2015.106 · Cited by 423
Self-citationTraboulsee, A., Simon, J. H., Stone, L., Fisher, E., Jones, D. E., Malhotra, A., Newsome, S. D., Oh, J., Reich, D. S., Richert, N., et al. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4539 · Cited by 340
Cited by
Serum neurofilament light chain predicts long term clinical outcomes in multiple sclerosis
Thebault, S., Abdoli, M., Fereshtehnejad, S.-M., Tessier, D., Tabard-Cossa, V., & Freedman, M. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-67504-6 · Cited by 161
Graph theoretical framework of brain networks in multiple sclerosis: a review of concepts
Fleischer, V., Radetz, A., Ciolac, D., Muthuraman, M., Gonzalez-Escamilla, G., Zipp, F., & Groppa, S. (2019) · Neuroscience · doi:10.1016/j.neuroscience.2017.10.033 · Cited by 151
Chronic inflammation in multiple sclerosis - seeing what was always there
Matthews, P. M. (2019) · Nature Reviews Neurology · doi:10.1038/s41582-019-0240-y · Cited by 128
Blood Neurofilament Light Chain: The Neurologist’s Troponin?
Thebault, S., Booth, R. A., & Freedman, M. S. (2020) · Biomedicines · doi:10.3390/biomedicines8110523 · Cited by 101
“Regular MRI scanning remains the gold standard means of detecting sub-clinical inflammatory lesions [49,50], but this costly and inconvenient test has a number of shortcomings.”
Background
Metadata
- Authors
- Igra, M. S., Paling, D., Wattjes, M. P., Connolly, D. J. A., & Hoggard, N.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-06
- Volume
- 90
- Issue
- 1074
- Pages
- 20160721
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2600162559
- Cited by
- 46
- References
- 3
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.